TEST 15: SERIAL PORT
15 SERIAL PORT
Install special
connector Z4.
Status: OFF
Check that the machine’s display indicates OFF.
Fit the special (Z4) serial test connector (accessories provided) to the machine’s serial port, checking that the
machine’s display indicates OFF to ON.
NOTE: if the ON/OFF transition is not made, contact Silca’s Technical Assistance Dept.
TEST 16: BATTERY STATE
16 BATTERY STATUS
< CHARGED >
Check that the display shows <Charged >.
If the display shows <Flat> replace the battery (see Ch. 7.16).
NOTE:
the machine also works with a flat battery (the battery is used only for the function: Options
> Set Clock).