ATTENTION
Install cutter
U01W
•
A hard metal cutter is required. Press ENTER to continue.
5.10.3 ALARM MESSAGES
ALARM 1
Key not
properly
installed !
• Key blank not properly fitted in the loader, or not properly loaded onto the automatic clamp.
ALARM 2
Movement axis
not completely
zeroed!
•
The message indicates that there is a fault on the axis referred to (X, Y or B) due to:
- an obstacle impeding free movement of the axis to complete its run
- a fault on the limit switch (do the sensor TEST)
- a fault on the motor that moves the axis (do the motor TEST)
- break down of motor control on the electronic board (do the motor TEST)
ALARM 3
HIGH TEMPERATURE
Turn the
machine off !
•
The electronic control board has exceeded the maximum permitted temperature. Check the cooling fan (see
Ch. 7.1 Trouble shooting).
ALARM 4
I/O POWER
Check fuse F4 !
•
Indicates that the fuse has blown due to a short circuit in an inlet or outlet (Ch.7.8).
ALARM 5
DIGITAL OUTLET
Turn the
machine off !
•
Indicates a short circuit in port P (IN/OUT) (see Ch. 7.1 Trouble shooting)
ALARM 6
CUTTER MOTOR
Check fuse F1 !
•
Indicates that the fuse has probably blown (see Ch. 7.8).
Operating Manual
UC199
Copyright Silca 2012
67
Summary of Contents for UC 199
Page 81: ...Fig 82 Fig 83 Operating Manual UC199 Copyright Silca 2012 77...
Page 86: ...Fig 93 Operating Manual UC199 Copyright Silca 2012 82...
Page 94: ...Operating Manual UC199 Copyright Silca 2012 90...
Page 96: ...ELECTRICAL DIAGRAMS Operating Manual UC199 Copyright Silca 2012 92...
Page 97: ...Operating Manual UC199 Copyright Silca 2012 93...
Page 98: ...Operating Manual UC199 Copyright Silca 2012 94...
Page 99: ...Operating Manual UC199 Copyright Silca 2012 95...
Page 100: ...Operating Manual UC199 Copyright Silca 2012 96...
Page 101: ...Terminal board connection Operating Manual UC199 Copyright Silca 2012 97...
Page 102: ...UC199 KEY CUTTING MACHINE OPTIONAL LOADER UNIT Operating Manual UC199 Copyright Silca 2012 98...
Page 103: ...Operating Manual UC199 Copyright Silca 2012 99...