Fig. 52
Lower the gauge and press START; the display will show first:
TEST key check
in progress !
And then:
To compare detected
quotes fit Gauge Z20
on reader clamp.
[START]
Remove the key from the reading clamp and fit the Z20 template in its place.
Fig. 53
ATTENTION: carefully clean the Z20 template, test key Z3 and clamps before gauging.
Lower the gauge and press START; the display will show first:
Gauge dimensions
reading in progress.
and then:
Adjustements:
X =-005 Y= +002
Save data?
No=STOP Yes=ENTER
The display will show the adjustments relating to the X and Y axes; the correction values are viewed automatically
(they are the difference between the value read on the key and the template value) (Fig. 54).
Fig. 54
Press ENTER to save the adjustments, which will be applied automatically to the cutting side L100 clamp.
ATTENTION: if the STOP key is pressed, the new settings will be lost. If so, only the previous
setting values will remain valid. The settings will be accepted only if the tolerances remain
within a range between -40/ +40 hundredths of a mm.
Operating Manual
UC199
Copyright Silca 2012
44
Summary of Contents for UC 199
Page 81: ...Fig 82 Fig 83 Operating Manual UC199 Copyright Silca 2012 77...
Page 86: ...Fig 93 Operating Manual UC199 Copyright Silca 2012 82...
Page 94: ...Operating Manual UC199 Copyright Silca 2012 90...
Page 96: ...ELECTRICAL DIAGRAMS Operating Manual UC199 Copyright Silca 2012 92...
Page 97: ...Operating Manual UC199 Copyright Silca 2012 93...
Page 98: ...Operating Manual UC199 Copyright Silca 2012 94...
Page 99: ...Operating Manual UC199 Copyright Silca 2012 95...
Page 100: ...Operating Manual UC199 Copyright Silca 2012 96...
Page 101: ...Terminal board connection Operating Manual UC199 Copyright Silca 2012 97...
Page 102: ...UC199 KEY CUTTING MACHINE OPTIONAL LOADER UNIT Operating Manual UC199 Copyright Silca 2012 98...
Page 103: ...Operating Manual UC199 Copyright Silca 2012 99...