background image

 

EtherHaul 1200™ 

Gigabit Ethernet Wireless Solution 

 

Installation and User Manual 

 

 

 

 

EH-INST-02, Issue 4.0 

December 2012 

 

 

 

 

Summary of Contents for EtherHaul 1200

Page 1: ...EtherHaul 1200 Gigabit Ethernet Wireless Solution Installation and User Manual EH INST 02 Issue 4 0 December 2012...

Page 2: ...tributed in any form or by any means or stored in a database or retrieval system without the prior written consent of Siklu Disclaimers The information contained in this document is subject to change...

Page 3: ...e with the requirements of European Directive 1995 5 EC This product has been designed to comply with the requirements of European Directives This equipment must be permanently earthed for protection...

Page 4: ...to make locating reading and using information easier Special Attention Hint Informs you of a helpful optional activity that may be performed at the current operating stage Note Provides important an...

Page 5: ...Grounding the EtherHaul 1200 29 2 7 2 Power Supply Notes 29 2 7 3 Preparing the Cables 30 2 7 4 Removing Connectors from the EtherHaul ODU 31 2 7 5 Connecting the Power 31 2 7 6 Connecting Other Inter...

Page 6: ...uring Interface Parameters 54 4 6 2 Displaying Interface Status 54 4 7 Default VLAN Setting 55 5 Commissioning and Acceptance Procedure 56 5 1 Installation Verification and Testing 56 5 1 1 Physical I...

Page 7: ...nce End Points MEPS 90 7 2 6 Working with Peer MEPs 92 7 2 7 Working with CCM Messages 93 7 2 8 Working with Linktrace Messages 94 7 2 9 Sample CFM Configuration 95 7 3 Configuring Link OAM 103 7 3 1...

Page 8: ...Key 131 9 1 2 Setting up a Static Key 131 9 2 Working with Configuration Files 132 9 2 1 Saving Configurations 132 9 2 2 Viewing Configurations 132 9 2 3 Restoring the Default Configuration 132 9 2 4...

Page 9: ...1 Loopback Diagrams 161 11 Using the EtherHaul CLI 164 11 1 Invoking the CLI 164 11 2 CLI Command Syntax 165 11 2 1 Basic Conventions 165 11 2 2 Common Syntax Rules 166 11 2 3 Repeatedly Used Identifi...

Page 10: ...ect Attributes 211 11 12 1 Ethernet Interface Attributes 211 11 12 2 Ethernet Statistic Descriptions 217 11 12 3 Bridge Object Attributes 218 11 12 4 Bridging Port Object Attributes 218 11 12 5 Outgoi...

Page 11: ...Configuration and System Screen 39 Figure 3 5 Add IP Window 40 Figure 3 6 Add Route Window 40 Figure 3 7 Web EMS Quick Configuration Screen Radio Section 42 Figure 3 8 Web EMS System Screen Radio Sec...

Page 12: ...creen Alarms Section 119 Figure 8 2 Events Screen Logs Section 120 Figure 8 3 Events Configuration Screen 121 Figure 8 4 RF Statistics Screen Current Tab 122 Figure 8 5 RF Statistics Screen History Ta...

Page 13: ...m Screen SNMP Managers Section 150 Figure 9 16 Web EMS System Screen SNMP Agent Section 151 Figure 9 17 Web EMS System Screen SNMP Users Section 152 Figure 10 1 EtherHaul 1200 System Loopback Points 1...

Page 14: ...industry The following are just some of the highlights of the EtherHaul 1200 system Operates in the licensed uncongested and inexpensive 71 76 GHz E band Carrier grade Gigabit Ethernet radio Revoluti...

Page 15: ...ment As a bonus licensing registration processes for this band are cheaper simpler and quicker With 1 Gbps throughput the EtherHaul 1200 radio future proofs the backhaul network to meet the growth in...

Page 16: ...band 71 76 GHz wireless spectrum with significantly lower licensing fees and simpler and quicker licensing registration processes for rapid service deployment 1 Gbps throughput delivers enough capacit...

Page 17: ...a pay as you grow basis Supporting point to point daisy chain ring and mesh configurations the EtherHaul system offers carrier class availability and services The following are some of the main featu...

Page 18: ...g networks and multi vendor interoperability Seamless software upgrades to MPLS IP and beyond Carrier Grade CLI SNMP or web based local and remote management Extremely high reliability with high MTBF...

Page 19: ...nal PHY The networking engine is the heart of the high speed bridge router function The engine receives packets from both Ethernet interfaces and from the modem It is responsible for proper forwarding...

Page 20: ...idge settings capabilities are enabled by default and do not require a license The software licenses are serial number dependent 1 5 Management You can manage an EtherHaul 1200 system using a Web Base...

Page 21: ...Installation and User Manual EH INST 02 Issue 4 0 1 6 Technical Specifications For detailed technical specifications please refer to the datasheet...

Page 22: ...nd prepare each EtherHaul ODU site to make device installation and configuration as simple and trouble free as possible During site selection and preparation always consider the long term needs of bot...

Page 23: ...bles DC and Ethernet on their entrance to the building Install the EtherHaul ODU in a location where proper electrical outdoor grounding is readily available Typically the grounding connection is atta...

Page 24: ...h the radome It is crucial to prevent contact between the radome and other objects 2 4 Required Tools Ensure that you have the following tools with you when performing an EtherHaul installation Standa...

Page 25: ...Where Ptx ODU s Tx Power typically 5dBm Gant1 Gain of antenna 1 in dBi Gant2 Gain of antenna 2 in dBi LFS Loss of Free Space 92 45 20 Log DKm FGHz D Link distance in Km F Frequency in GHz Attatm Atten...

Page 26: ...zimuth Fine Adjustment Screw 8 4 Quick Release Plate Attached to ODU 9 Elevation Fine Adjustment Screw 16 5 Quick Release Hooks 10 Elevation Screw Tension Band and Pin Figure 2 1 EtherHaul 1200 Mounti...

Page 27: ...ODU 7 Examine the position scales of both the Azimuth Adjustment Lock Bolts and the Elevation Adjustment Lock Bolts found on the Front Mounting Bracket and ensure that they are positioned at 0 degree...

Page 28: ...ower over Ethernet PoE connection can only be made via the first Ethernet RJ45 interface RJ1 1 Electrical Ground Outlet GND 6 Ethernet Cable RJ45 Interface RJ2 2 Power Connector Interface PWR 7 Fiber...

Page 29: ...le install an alternative cable Figure 2 4 ODU with Grounding Cable Connected 2 7 2 Power Supply Notes The DC power input range of the ODU is 21 57 VDC The DC supply should be limited to 2 Ampere to a...

Page 30: ...he ODU On the ODU DC terminal connect only the and wires Do not connect to the ODU s GND input Caution Disconnect all power cables before service 2 7 3 Preparing the Cables Before inserting a cable co...

Page 31: ...ion to the Connector Outlet Portion firmly by hand do not use tools 2 7 4 Removing Connectors from the EtherHaul ODU Caution To avoid accidental damage to the connector always use the following order...

Page 32: ...he RJ45 or SFP connector into the port 3 Screw the Cable Inlet Portion of the All Weather Shell onto the secured top portion taking care not to twist the connecting cable 4 Tighten the bottom portion...

Page 33: ...U some freedom of movement 3 Perform a coarse ODU alignment using a line of sight visual check with the remote EtherHaul ODU Lock the Unit Mounting Bolts using the 13mm open wrench 4 Repeat Steps 1 to...

Page 34: ...DU 9 Repeat Steps 6 and 7 for the local ODU 10 Use the DVM to verify maximum received signal strength on both local and remote ODUs For best performance measured RSSI should be within 4 dB of the calc...

Page 35: ...Reset Button This returns the ODU to Adaptive Mode Following this action and after the ODU has finished rebooting the RF LED color indicator on both ODUs will turn green indicating that the radio lin...

Page 36: ...s chapter includes the following topics Connecting to the ODU Using the Web EMS Saving Configuration Changes and Resetting the System Using the Web EMS Quick Configuration Configuring and Displaying B...

Page 37: ...Web EMS Main screen is displayed Figure 3 1 Web EMS Main Screen 3 2 Saving Configuration Changes and Resetting the System Using the Web EMS Whenever you make changes to the ODU configuration using th...

Page 38: ...more extensive system parameters 3 4 Configuring and Displaying Basic System Information Using the Web EMS You can view and configure basic system information in the System Information section of the...

Page 39: ...iguration screen or by clicking System on the Web EMS Main screen and clicking the IP section of the System screen The EtherHaul ODU supports up to four IP addresses that can be on different subnets a...

Page 40: ...ge it Note If you change the default IP address your connection to the ODU will be lost To re establish a connection launch an Internet browser and connect using the new IP address 3 Click Apply Note...

Page 41: ...ask 255 255 255 0 and default gateway 192 168 0 254 ODU config IP screen Index 1 IP Address 192 168 0 17 Prefix Lenght 24 VLAN 0 ODU config Route screen Index 1 Destination 0 0 0 0 Prefix Length 0 Nex...

Page 42: ...to the Radio section of the Radio screen The Radio screen displays several additional fields Figure 3 8 Web EMS System Screen Radio Section Frequency MHz Select a frequency channel The default values...

Page 43: ...r Channel Width 500MHz 125 500MHz Repetitions 1 2 or 4 FEC Rate 0 5 When using the system in Static mode you must select from a pre defined list of modulation profiles In Adaptive mode the ODU will sw...

Page 44: ...Web EMS Main screen and click the Modulations section of the Radio screen Note that different modulation tables may apply according to the frequency channel used Figure 3 9 WEB EMS Radio Screen Modula...

Page 45: ...section lists and describes those parameters that can be modified Figure 3 10 Web EMS Quick Configuration Screen Port Section Eth1 You can also configure Ethernet port parameters by clicking the icon...

Page 46: ...to negotiation and Ethernet Speed Duplex in case Auto neg disabled must be identical on the ODU port and the end equipment port Loopback Mode Interface screen only Options are Disabled Internal Intern...

Page 47: ...are applicable for SNMPv2 Refer to the Managing SNMP section for SNMPv3 settings 3 10 Default VLAN Setting EtherHaul s Undefined VLAN feature enables transparent forwarding of both tagged and untagged...

Page 48: ...Information Using the CLI Configuring System IP Addresses Using the CLI Configuring Radio Parameters Using the CLI Configuring Ethernet Interfaces Using the CLI Default VLAN Setting Note Before you pe...

Page 49: ...xit Alignment mode Local_Site reset system 4 3 Configuring and Displaying Basic System Information Using the CLI Use the set system name command to set the ODU s name Once you set the ODU s name a pro...

Page 50: ...Site set ip 1 ip addr 192 168 0 11 prefix len 24 If the IP entry does not already exist the set ip command creates it and assigns the attributes specified If the interface address or the default route...

Page 51: ...0 64 prefix len 30 next hop 192 168 0 66 To set a single default gateway use the following command When single IP is used and a Static route is not used you may configure a default IP gateway In such...

Page 52: ...0 rf temperature 52 rf loopback timeout 60 rf loopback disabled rf tx power 5 Table 11 3 on page 192 lists and describes the configurable RF attributes Table 11 5 on page 193 lists and describes the...

Page 53: ...w modulation command to display available supported modulation profiles and their parameters CINR Low Lower threshold for stepping down in modulation profile Adaptive Mode CINR High Upper threshold fo...

Page 54: ...1 Configuring Interface Parameters Use the set eth command followed by the name of the interface Eth1 or Eth2 to change the default values of an Ethernet interface set eth eth list admin up down alias...

Page 55: ...k mode disabled eth eth1 loopback timeout 60 eth eth1 alarm propagation disabled Table 11 18 on page 211 lists and describes the configurable Ethernet interface attributes Table 11 19 on page 214 list...

Page 56: ...erence to requirements that are detailed in the accompanying checklist EtherHaul Commissioning and Acceptance Form on page 58 Hint Make copies of the EtherHaul Commissioning and Acceptance Form on pag...

Page 57: ...inspection verifies correct Ethernet services flow and error free operation Connect PCs on both ends of the link and use software based utilities to test for packet loss If available connect a packet...

Page 58: ...line of sight Yes No Yes No ODU safely mounted using Siklu s bracket correctly installed Yes No Yes No Pole diameter between 2 4 Yes No Yes No Bracket s mounting bolts securely tightened Yes No Yes No...

Page 59: ...idth 250MHz 500MHz 250MHz 500MHz Role Auto Master Slave Auto Master Slave Tx Rx Link ID 0 not used 0 not used Modulation Mode Mode modulation sub channel repetitions FEC Adaptive ____________ Static _...

Page 60: ...unters clear Yes No Yes No Management IP address Mask IP Mask Default IP Gateway In band management enabled Yes No VLAN ID ___________ Yes No VLAN ID ___________ Management of local and remote Yes No...

Page 61: ...Installation and User Manual EH INST 02 Issue 4 0 I C Details I C Date Installation team Commissioning team...

Page 62: ...m multiple customers to be forwarded or tunneled through another topology provider network using service VLANs or S VLANs The provider bridge which may consist of multiple devices in the service provi...

Page 63: ...he generic model of the EtherHaul bridge Figure 6 2 Generic Model of the EtherHaul Bridge Each component acts as a virtual bridge A component can have both external and internal ports An external port...

Page 64: ...nge your VLANs with no additional configuration necessary in the EtherHaul system In addition to the default Transparent Bridge feature you can choose to create VLANs as well as block specific VLANs 6...

Page 65: ...default show vlan component id vid fdb id egress untagged history s1 1 1 c1 c2 c3 c4 c1 c2 c3 c4 disable s1 undef 1 c1 c2 c3 c4 none disable c1 1 1 host s1 host disable c1 undef 1 host s1 none disable...

Page 66: ...e Add VLAN window is displayed Figure 6 7 Add VLAN Window 4 Configure the following VLAN attributes for the required components VID C VLAN Identifier This can be any number from 1 to 4094 which identi...

Page 67: ...VLAN select enable Otherwise select disable 5 Click Apply to close the Add VLAN window 6 Click Apply to implement the changes and close the Bridge screen 6 3 3 Configuring VLANs Using the CLI 6 3 3 1...

Page 68: ...c3 1 1 eth1 s1 eth1 disable c3 333 1 none none disable c3 undef 1 eth1 s1 none disable c4 1 1 eth2 s1 eth2 disable c4 333 1 none none disable c4 undef 1 eth2 s1 none disable default 6 3 3 3 Deleting V...

Page 69: ...ntagged show vlan all vids info statistics fdb id egress untagged 6 3 3 5 VLAN Table Attributes Table 11 28 on page 223 lists and describes the attributes in the VLAN Table 6 3 3 6 Displaying VLAN Com...

Page 70: ...sing the Web EMS 1 In the Web EMS Main screen click Bridge The Bridge screen is displayed 2 Click the Bridge Ports section of the Bridge Ports screen Figure 6 8 Web EMS Bridge Screen Bridge Ports Sect...

Page 71: ...essentially asymmetrical Frames with any VIDs may enter through any port but leave only though a port which is a member in the egress set assigned to a particular VLAN By setting filter to enabled sy...

Page 72: ...he Ports eth2 and s1 The Ports associated with the Component s1 are dependent on the c components that currently exist For example if the components c1 and c4 already exist then the Component s1 is as...

Page 73: ...nt that an attribute is not explicitly specified the entry is created with the default value for that attribute If the PEP Virtual Port entry already exists then the set pep vp command replaces the at...

Page 74: ...not already exist the set svid xlat command creates it and assigns the attributes specified Upon creation in the event that an attribute is not explicitly specified the entry is created with the defau...

Page 75: ...for that attribute If the entry already exists then the set cvlan reg command replaces the attributes that are currently defined for the entry with those specified in the command Note the following c...

Page 76: ...set fdb s1 fdb id list aging aging time Use the following command to display FDB entries show fdb s1 fdb id list aging full table counter num of dynamic Table 11 33 on page 229 lists and describes th...

Page 77: ...le entries show fdb table s1 all fdb id list all mac addr all info port status Use the following command to delete FDB Address table entries and clear their associated statistics clear fdb table s1 al...

Page 78: ...cially important in wireless links with adaptive capabilities because changing link conditions may require the system to drop some traffic according to a predetermined priority and scheduling scheme E...

Page 79: ...t eth0 eth1 eth2 precedence 1 vid 0 4094 pcp 0 ip cos dont care cos 0 set classifier cos 2 interface host eth0 eth1 eth2 precedence 1 vid 0 4094 pcp 1 ip cos dont care cos 1 set classifier cos 3 inter...

Page 80: ...th0 eth1 precedence 1 vid 0 4094 pcp 1 ip cos dont care cos 1 set classifier cos 4 interface eth0 eth1 precedence 1 vid 0 4094 pcp 2 ip cos dont care cos 2 set classifier cos 5 interface eth0 eth1 pre...

Page 81: ...cos dont care evc 1 set classifier evc 2 interface eth0 precedence 1 vid 0 4094 pcp 1 ip cos dont care evc 2 set classifier evc 3 interface eth0 precedence 1 vid 0 4094 pcp 2 ip cos dont care evc 3 se...

Page 82: ...Burst Size bytes EBS Excess Burst Size bytes Color aware mode is supported for ingress S VLAN packets only based on MEF definitions Use the following command to configure a meter set meter meter id 1...

Page 83: ...ring the egress cos color drop blind or aware can be configured 7 1 3 1 Weighted Fair Queue WFQ Weighted Fair Queuing WFQ can be used to provide different rates to different flows while maintaining fa...

Page 84: ...ed load exceeds the radio link rate 480 320 Mbps The two highest queues Strict Priority 6 and 7 take precedence over WFQ queues The remaining bandwidth 320 60 60 200 Mbps is split among the weighted q...

Page 85: ...0 CIR CoS 2 20 20 Stream rate 40 CIR CoS 1 30 30 Stream rate 70 BE CoS 0 0 50 Total 370 320 The following is an example of Shaper Strict Priority configuration scheduler configuring set scheduler mode...

Page 86: ...includes the following topics CFM Overview Working with Maintenance Domains Working with Maintenance Associations Working with Component Maintenance Associations Working with Maintenance End Points W...

Page 87: ...re configured to create a Maintenance Association MA The MA monitors connectivity provided by that instance through the Maintenance Domain Maintenance Association Intermediate Points MIPs are the inte...

Page 88: ...cess points Each of the eight hierarchical Maintenance Domain Levels MD Level supports OAM capabilities independently Use the following command to set an MD Note that the name attribute must be unique...

Page 89: ...cfm ma md idx list all ma idx list all name component interval info Use the following command to clear a particular MA or all MAs clear cfm ma md idx list all ma idx list all Figure 7 9 CFM MA Setup...

Page 90: ...le disable ltm dst type mac mepid ltm dst mac mac addr ltm dst mepid mepid ltm tx ttl 0 250 lbm tx status tx pending tx idle ltm tx status tx pending tx idle Use the following command to display a par...

Page 91: ...e 4 0 Figure 7 11 CFM MEP Setup Table 11 12 on page 199 lists and describes the configurable MEP attributes Table 11 13 on page 203 lists and describes the read only MEP attributes You can display the...

Page 92: ...es in MEP table and this Peer MEP ID set cfm peer mep create md idx list ma idx list peer mepid list Use the following command to display Peer MEP information show cfm peer mep create md idx list all...

Page 93: ...xFCb If present Sender Chassis Subtype and ID Management Address Domain Management Address Port Status blocked up according to IEEE 802 1ag Table 21 10 Interface Status up down testing unknown dormant...

Page 94: ...limited arrival of a new message results in discarding older messages Entire groups that use the same sequence number are discarded Use the following command to display LTR database information show c...

Page 95: ...t cfm md 1 name string Link level 0 The following command creates an MA set cfm ma 1 1 name string Link interval 300hz The following command creates a Component MA and assigns VLAN 200 as its Service...

Page 96: ...es MIPS only on ports that have MEPs on their lower level Configuring the Remote ODU The first step in configuring CFM parameters is to enable the OAM license Without an enabled OAM license the necess...

Page 97: ...er mep 1 1 1 2 if status unknown cfm peer mep 1 1 1 2 chassis id subtype unknown cfm peer mep 1 1 1 2 mng addr domain unknown cfm peer mep 2 2 1 2 state ok cfm peer mep 2 2 1 2 failed ok time 0000 02...

Page 98: ...msg prio 0 cfm mep 1 1 1 low defect mac rem err xcon cfm mep 1 1 1 alarm time 250 cfm mep 1 1 1 reset time 1000 cfm mep 1 1 1 lbm dst mac 00 00 00 00 00 00 cfm mep 1 1 1 lbm dst mepid 2 cfm mep 1 1 1...

Page 99: ...w defect mac rem err xcon cfm mep 2 2 1 alarm time 250 cfm mep 2 2 1 reset time 1000 cfm mep 2 2 1 lbm dst mac 00 00 00 00 00 00 cfm mep 2 2 1 lbm dst mepid 2 cfm mep 2 2 1 lbm dst type mepid cfm mep...

Page 100: ...the number of replies according to their order of arrival Where several elements answer you must check the TTL to identify the trace Enter the following on the link level set cfm mep 1 1 1 ltm dst typ...

Page 101: ...5a cfm mep 2 2 1 0 0 next egr id 00 00 00 24 a4 00 07 59 cfm mep 2 2 1 0 1 rx ttl 62 cfm mep 2 2 1 0 1 ltr forward unknown cfm mep 2 2 1 0 1 relay action fdb cfm mep 2 2 1 0 1 chassis id subtype unkn...

Page 102: ...4 0 cfm mep 2 2 1 0 2 egr action none cfm mep 2 2 1 0 2 egr mac 00 00 00 00 00 00 cfm mep 2 2 1 0 2 egr port id subtype unknown cfm mep 2 2 1 0 2 trm mep unknown cfm mep 2 2 1 0 2 last egr id 00 00 00...

Page 103: ...nable Link OAM set link oam eth list eth0 eth1 eth2 admin value Enabled disabled default set link oam eth0 admin enabled To view Link OAM configuration and status default show link oam link oam eth0 a...

Page 104: ...initiated the remote loopback To set Link OAM loopback set link oam loopback eth list eth0 eth1 eth2 status value init terminate peer request value ignore process To allow ports to enter loopback stat...

Page 105: ...Installation and User Manual EH INST 02 Issue 4 0 default show link oam loopback eth0 link oam loopback eth0 status none link oam loopback eth0 peer request process...

Page 106: ...sed for transmission on all interfaces propagating the clock in the path Every SyncE Network Element contains an internal clock called the Ethernet Equipment Clock EEC The EEC locks on the Rx clock an...

Page 107: ...attribute determines the priority of the reference clock source in the event that there is an equal ql among the interfaces The priority can be any value from 1 to 255 where 1 is the highest priority...

Page 108: ...ctive backup 1 2 3 down ql actual The current ql of the active interface ql config 0 to 15 Sets the ql of the interface ql mode Can be Enabled enable or Disabled disable ssm cvid the C VLAN ssm messag...

Page 109: ...DNU Do Not use ql 15 is returned to the source in order to prevent timing loops Figure 7 17 Typical SyncE Scenario The configuration for this scenario is Local EtherHaul 1200 Default show ref clock re...

Page 110: ...lock eth0 ql config 14 ref clock eth0 ql mode enable ref clock eth0 ssm cvid none Figure 7 18 illustrates a SyncE scenario in which there is a holdover situation due to radio failure The local EtherHa...

Page 111: ...t ql actual 11 ref clock host ql config 11 ref clock host ql mode disable ref clock host ssm cvid none ref clock eth0 prio 100 ref clock eth0 status down ref clock eth0 ql actual 15 ref clock eth0 ql...

Page 112: ...e ref clock host ql actual 11 ref clock host ql config 11 ref clock host ql mode disable ref clock host ssm cvid none ref clock eth2 prio 200 ref clock eth2 status down ref clock eth2 ql actual 15 ref...

Page 113: ...ent Classification Default Severity Destination Reference Clock Switch Event N A Trap ref clock switch Log Reception of QL EEC1 or Worse Alarm indicating a previous element in the chain is in holdover...

Page 114: ...prevents loops within the ring by blocking one of the links either a pre determined link or a failed link ERP verifies at all times the ring is closed that frames will not be looped This is accomplish...

Page 115: ...ing statistics use the following command Default show ring all statistics ring 1 raps tx 1443 ACW RPL owner originate RAPS ring 1 raps rx 1443 Received RAPS ring 1 local sf cnt 0 Signal Failure ring 1...

Page 116: ...d at an RPL owner node to trigger reversion The following examples illustrate how to use the administrative commands to control manual switching to the backup and block a particular ring port Left_Sla...

Page 117: ...for delaying switching triggered by administrative command FS MS 5000 7000 mSec in 100mSec steps Wait to Restore Timer for delaying revertive operation 1 12 minutes 7 5 5 ERP Configuration Example Th...

Page 118: ...le ring 1 last state time 2011 06 27 ring 1 idle percent 97 658112 ring 1 protect percent 1 230652 ring 1 ms percent 0 000000 ring 1 fs percent 0 000000 ring 1 pending percent 1 111240 ring 1 cw node...

Page 119: ...b EMS or the CLI For a detailed explanation of EtherHaul events and alarms and instructions on how to use them in diagnosing EtherHaul system problems refer to EtherHaul Diagnostics on page 153 To dis...

Page 120: ...alarm or event occurred Figure 8 2 Events Screen Logs Section To display a log of alarms and system events using the CLI use the show log command A log of alarms and system events appears including th...

Page 121: ...e status low mask no event cfg loopback enabled mask no event cfg tx mute enabled mask no event cfg ql eec1 or worse mask no event cfg cold start mask no event cfg modulation change mask no event cfg...

Page 122: ...omatic Repeat reQuest algorithm uses selective repeat retransmission to eliminate radio BER The arq in loss and arq out loss indicate frame loss over the radio that can be noticed by the Ethernet serv...

Page 123: ...b 8 4 2 Viewing a Statistics Summary Using the Web EMS You can display a summary of the ODU s radio statistics in graph or table format using the Web EMS To display a summary of the ODU s radio statis...

Page 124: ...ctets 9370230 rf in errored octets 0 rf out octets 30552267600 rf out idle octets 30531707551 rf in pkts 129957 rf in good pkts 129452 rf in errored pkts 0 rf in lost pkts 0 rf out pkts 231519 rf min...

Page 125: ...on 0 2011 03 17 10 22 58 76 33 15 18 qpsk 1 4 0 5 qpsk 4 1 0 5 unknown 1 2011 03 17 10 07 57 76 24 128 128 qpsk 1 4 0 5 qpsk 1 4 0 5 unknown 2 2011 03 17 09 52 56 76 10 128 128 qpsk 1 4 0 5 qpsk 1 4 0...

Page 126: ...how out queue eth1 all statistics interface qid tx drop elapsed time eth1 1 1321 3 0001 02 15 09 eth1 2 1543 1 0001 02 15 09 eth1 3 1435 0 0001 02 15 09 eth1 4 2345 0 0001 02 15 09 eth1 5 4563 0 0001...

Page 127: ...all are valid for the second ID If all is specified only four queues are displayed Use the following command to clear the incoming queue statistics clear in queue rf all 1 4 all statistics Table 11 25...

Page 128: ...CLI use the following command show eth eth list statistics Table 11 21 on page 217 lists and describes the Ethernet statistics 8 8 Viewing Bandwidth Utilization Statistics You can display statistics...

Page 129: ...tistics show eth eth list statistics summary start ifc in octets out octets in rate out rate util 0 2012 12 05 01 01 10 eth0 747984743210 748161700832 1765192 1766392 1 0 To display the bandwidth util...

Page 130: ...ion rather than the network itself and includes the following topics Configuring Encryption Working with Configuration Files Configuring Users Upgrading the ODU Software Monitoring CLI Sessions Viewin...

Page 131: ...supports AES encryption protocol which is capable of delivering encrypted transmission over the link 9 1 1 Loading Encryption License Key Encryption is a licensed feature that requires a license for o...

Page 132: ...EMS main screen Default copy running configuration startup configuration running configuration copied to startup configuration 9 2 2 Viewing Configurations You can display either the running or the d...

Page 133: ...the timeout period the system automatically resets and wakes up with the saved startup configuration Note that the rollback timer resets to zero after each new CLI command The rollback timer expires...

Page 134: ...s The user type defines the user s access privileges User Read only access but cannot view user names passwords and other security settings Tech Read only access to configuration settings Can clear st...

Page 135: ...s enables you to upgrade the software with minimal interruption of service An external FTP server is required for software download When you download a software version the downloaded version replaces...

Page 136: ...oftware versions The software version is followed by the creation date and time of the version The first digit of the version number represents the major version number the second digit represents the...

Page 137: ...d copy sw from url to copy a specified software version to the ODU where from url represents the URL of the FTP server which you are downloading the new software version The software version image is...

Page 138: ...following command to display active CLI sessions show loginsession my all In response the software displays the following Session ID Session Time xx dddd hh mm ss yy dddd hh mm ss Where xx or yy is a...

Page 139: ...name Siklu inventory 1 model name EH 1200 ODU 2ft inventory 1 fru true 9 6 1 Viewing System Inventory Using the Web EMS To view the ODU s inventory list using the Web EMS 1 In the Web EMS Main screen...

Page 140: ...py license ftp_user ftp_password FTP server IP address license_file_name finished Once you have loaded the license file to the ODU you can activate the license To view the available licenses according...

Page 141: ...eation in the event that the interface address or the default router address is not specified the entry is created with the default value that has been defined for the VLAN If the ARP entry already ex...

Page 142: ...ervers To specify a file on a network server use one of the following forms ftp username password Location subdirectory filename The location can be an IP address or a host name The file path director...

Page 143: ...ice works only for flash and eprom available to all types of users copy from url to url Copy file root admin and super are allowed to copy from any device to any device Tech and user are allowed to co...

Page 144: ...e_cfg 5 5613 02 03 2011 08 51 19 startup configuration txt 6 566 02 03 2011 08 51 19 startup debug configuration txt 7 5688 02 03 2011 16 51 45 scripts clear_statistics 8 2121 25 02 2011 08 50 24 scri...

Page 145: ...copy them to the system The script must consist of valid CLI commands To include comments in the script type at the beginning of the line The following is an example of a command line script Demo Scri...

Page 146: ...rectly from the CLI To view the content of a script transfer the script to the server and view it with a text editor In the same manner you cannot edit scripts directly on the ODU To edit a script tra...

Page 147: ...ript content directly from the CLI To view the content of a script transfer the script to the server and view it with a text editor Default copy flash scripts DemoScript txt ftp srv admin 192 168 0 10...

Page 148: ...r Name and the command Upon execution of each SNMP set request a CLI command functionally equivalent to the SNMP set request will be constructed and added to the log In case of SNMPv2 the write commun...

Page 149: ...3 09 06 36 sw cad User cli admin copy running configuration startup configuration Dec 23 09 13 09 sw cad User cli admin clear log Dec 24 02 36 48 sw cad User cli admin set rf mode alignment Dec 24 02...

Page 150: ...snmp mng 1 5 ip addr value udp port 0 65535 snmp version v2 v3 security name value engine id value Security name is trap community name in the case of SNMPv2 and user name in the case of SNMPv3 Defaul...

Page 151: ...SNMP users settings set snmp user engine id user auth priv engine id local string auth none md5 passphrase sha passphrase priv none des passphrase aes passphrase auth passphrase and privacy passphras...

Page 152: ...Installation and User Manual EtherHaul 1200 Page 152 EH INST 02 Issue 4 0 Figure 9 17 Web EMS System Screen SNMP Users Section...

Page 153: ...and resolve operating faults in the ODUs or in the EtherHaul network The chapter includes the following topics The Troubleshooting and Diagnostics Process EtherHaul ODU LEDs EtherHaul System Alarms an...

Page 154: ...nfiguration settings this can be verified using the CLI A hardware fault in one of the ODUs A result of larger network propagation problem Note that Loopback indications are especially useful when iso...

Page 155: ...with a description for purposes of diagnostics LED Color Description PWR Power Green Power OK Blink Green Device boot Red Power Failure Off No Alarms RF Green Link Up Blink Green RF activity Orange A...

Page 156: ...A N A Link Down Alarm High Trap Log Active Alarm List The communication link either the RF or one of the Ethernet ports is not operational Ethernet 1 A cable is disconnected 2 Configuration mismatch b...

Page 157: ...k the ODU installation and verify that it is installed in accordance with environmental specifications 2 Replace ODU Temperature Normal Event Trap Log The temperature of the device has returned to the...

Page 158: ...to the PoE 2 Check cable 3 Replace PoE 4 Replace ODU POE Status Normal Event Trap Log The power level being drawn by the ODU from the Ethernet is normal N A N A ERP Ready Event Trap Log ERP is ready f...

Page 159: ...more details on system statistics refer to Monitoring the System on page 119 10 4 1 RF Statistics Check RF statistic counters to identify radio errors and check the radio status history The RF statis...

Page 160: ...224 196 0 0000 00 00 32 Observe the in pkts out pkts and dropped pkts for each VLAN Note that packets may be dropped due to traffic exceeding the radio link s maximum bandwidth For detailed explanati...

Page 161: ...l loopback is performed on the ODU s RF output Note After activating Loopback it is important to clear all RF and Ethernet statistics in order to receive the most accurate results for analysis Use sys...

Page 162: ...be set with MAC Address swapping and on specific modulation profile Set the loopback mode on the RF menu and set the loopback timeout in seconds set rf loopback timeout 300 set rf loopback mode intern...

Page 163: ...loopback mode to internal for the desired Ethernet port and set the loopback timeout in seconds set eth eth1 loopback timeout 300 set eth eth1 loopback mode internal mac swap Use the following command...

Page 164: ...l Statistics History CLI Managed Object Reference Management Object Attributes Radio Object Attributes Encryption Object Attributes Connectivity Fault Management CFM Object Attributes Network Object A...

Page 165: ...er s for the object s on which action s will be performed 4 Zero or more object attributes that typically specify the value or characteristics for each action A CLI command line typically uses the fol...

Page 166: ...1 bridge port A single port name one of host eth0 eth1 eth2 c1 c2 c3 c4 c4 s1 fdb id A single FID number from 1 to 64 vid A single VID number from 1 to 4094 mac addr A MAC address in the form NN NN NN...

Page 167: ...C address in the form NN NN NN NN NN NN where N is a hexadecimal number e g 00 AF DD 1E 2D A3 ip addr A standard dotted notation IP address e g 10 0 15 74 ip mask The IP address mask i e the number of...

Page 168: ...es specified Upon creation in the event that an attribute is not explicitly specified the entry is created with the default value for that attribute If the dynamic object already exists then the Set c...

Page 169: ...ired for correct command interpretation For example show vlan 123 170 will not be correctly autocompleted because it lacks a required reference to the object s1 When a show command is entered with the...

Page 170: ...reboot activities Reset RF Resetting the RF returns the radio and modem hardware to its default settings The command does not change a system configuration Default reset rf Reset RF is required whenev...

Page 171: ...ge port s1 c3 refers to Port c3 on Component s1 The following lists all named objects used in the CLI together with the EtherHaul objects that they reference CLI Name Referenced Object eth0 Wireless p...

Page 172: ...ause two different C components cannot be associated with the same port 11 2 6 2 Designating Indexed Objects Countable EtherHaul CLI objects are specified by their unique identifying keyword followed...

Page 173: ...s the entire object range For example vlan all is identical to vlan 1 4094 11 2 6 3 Multi Dimensional Objects with Indexes The CLI supports multi dimensional objects with numerical indexes If they app...

Page 174: ...You can explicitly request autocompletion assistance on the command line The CLI command interpreter always checks the validity and completeness of a string that is entered on the command line When a...

Page 175: ...relevant for s vlans only Following printout the CLI prompts you with the command that was input Default set vlan xxx string tab Automatically completes a specific command name For example Default set...

Page 176: ...how cfm mep show cfm ccm show cfm peer mep db Default sh i Invalid input This error occurs when the command entered includes an attribute value that is outside of the range allowed To assist you the C...

Page 177: ...the requested object statistics When a statistics interval is requested the CLI returns information in the following format Interval Start End num time time Where num is the interval number from 0 to...

Page 178: ...his section describes all EtherHaul System objects that can be created modified displayed or deleted using the command line interface Use Figure 11 1 to quickly identify and locate a specific EtherHau...

Page 179: ...network management subsystem contained in the entity sysObiectID 1 3 6 1 2 1 1 2 1 3 6 1 4 1 31926 RO 1 3 6 1 4 1 31926 System Up Time up time The length of time that has passed since the network mana...

Page 180: ...tring RW Default System Location location The physical location of this node e g telephone closet 3rd floor sysLocation 1 3 6 1 2 1 1 6 Up to 256 characters If no system location exists the value retu...

Page 181: ...stinct value for each version or model of the physical entity entPhysicalDescr 1 3 6 1 2 1 47 1 1 1 1 2 character string character string Contained In cont in The value of entPhysicalIndex for the phy...

Page 182: ...werSupply 6 fan 7 sensor 8 module 9 e g plug in card or daughter card port 10 stack 11 e g stack of multiple chassis entities cpu 12 other unknown chassis backplane container power supply fan sensor m...

Page 183: ...e then this object contains a zero length string entPhysicalName 1 3 6 1 2 1 47 1 1 1 1 7 character string character string Physical Hardware Revision hw rev The vendor specific hardware revision stri...

Page 184: ...f this information is unknown to the agent then this object will contain a zero length string entPhysicalFirmwareRev 1 3 6 1 2 1 47 1 1 1 1 9 character string character string Physical Software Revisi...

Page 185: ...1 11 character string up to 32 chars character string up to 32 chars Physical Manufacturer Name mfg name The name of the manufacturer of this physical component The preferred value is the manufacturer...

Page 186: ...omponents permanently contained within a field replaceable unit the value false 2 should be returned for this object entPhysicalIsFRU 1 3 6 1 2 1 47 1 1 1 1 16 true 1 false 2 replaceable not replaceab...

Page 187: ...3 1 Overall Product Attribute Value Inventory Index 1 Descriptor Siklu EH 1200 Contained In 0 Class chassis Parent Relative Position 1 Name EH 1200 Hardware Revision empty Firmware Revision empty Sof...

Page 188: ...ion empty Serial Number empty Manufacturer Name Siklu Model Name empty Field Replaceable Unit Indicator not replaceable 11 8 3 3 RF IC Attribute Value Inventory Index 3 Descriptor Siklu EH 1200 RF IC...

Page 189: ...Software Revision empty Serial Number to be read in runtime Manufacturer Name Siklu Model Name empty Field Replaceable Unit Indicator not replaceable 11 8 3 5 Modem Attribute Value Inventory Index 5 D...

Page 190: ...me Software Revision empty Serial Number empty Manufacturer Name empty Model Name empty Field Replaceable Unit Indicator not replaceable 11 8 3 7 CPLD Attribute Value Inventory Index 7 Descriptor Sikl...

Page 191: ...n empty Serial Number empty Manufacturer Name to be read in runtime Model Name empty Field Replaceable Unit Indicator replaceable 11 8 3 9 Boot Attribute Value Inventory Index 8 Descriptor Siklu EH 12...

Page 192: ...is specified on the command line the CLI will respond with the modulation does not exist in the modulation table rfModeSelector 1 3 6 1 4 1 31926 2 1 1 6 adaptive static alignment When static mode is...

Page 193: ...1 3 6 1 4 1 31926 2 1 1 10 Table 11 5 Read Only RF Attributes Attribute CLI Attribute Name Description SNMP Object ID Value Default Channel Width channel width The channel width expressed in MHz rfCha...

Page 194: ...tets transmitted to the RF link rfOutOctets 1 3 6 1 4 1 31926 2 2 1 5 Outgoing Idle Octets out idle octets The total number of octets transmitted to the RF link while idle rfOutIdleOctets 1 3 6 1 4 1...

Page 195: ...rfOutPkts 1 3 6 1 4 1 31926 2 2 1 11 11 10 Encryption Object Attributes Table 11 8 Encryption Attributes Attribute CLI Attribute Name Description SNMP Object ID Syntax Access Default Encryption Encry...

Page 196: ...tenance Domain dot1agCfmMdName 1 3 111 2 802 1 1 8 1 5 2 1 1 dns like mac and unit string name according to format RC Empty Format format Represents a type and the resulting format of the MD Name Can...

Page 197: ...at represents a type and the resulting format of the MD Name dot1agCfmMaNetFor mat 1 3 111 2 802 1 1 8 1 6 1 1 2 vid string vpnid RW vid MA Name name The short MA name The type format of this object i...

Page 198: ...the MP is attached or 0 if none The type of the Service Selector is defined by the value of ieee8021CfmMaCompPrimarySelect orType In the current implementation the type is always VLAN ID Thus the Ser...

Page 199: ...or LTR DB dot1agCfmMaIndex 1 3 111 2 802 1 1 8 1 6 1 1 1 N A MEPID An integer that is unique for all the MEPs in the same MA that identifies a specific MA End Point Adding an entry with a specific MEP...

Page 200: ...7 dot1agCfmMepCci Enabled enabled disabled RC disabled Message Priority msg prio The priority value for CCMs and LTMs transmitted by the MEP The default value is the highest priority value allowed pa...

Page 201: ...ransmit lbm tx num The number of Loopback messages to be transmitted 1 3 111 2 802 1 1 8 1 7 1 1 30 dot1agCfmMepTra nsmitLbmMessages 1 1024 RC 1 LBM Data TLV lbm tx data An arbitrary amount of data to...

Page 202: ...and if 0 no LTR is generated 1 3 111 2 802 1 1 8 1 7 1 1 41 dot1agCfmMepTra nsmitLtmTtl 0 250 RC 64 Transmit LBM Status lbm tx status A Boolean flag set to True by the Bridge Port to indicate that an...

Page 203: ...802 1 1 8 1 7 1 1 17 dot1agCfmMepCcmSequenc eErrors Integer CCM Transmit Counter ccm tx Total number of Continuity Check messages transmitted 1 3 111 2 802 1 1 8 1 7 1 1 18 dot1agCfmMepCciSentCcms Int...

Page 204: ...sed as the index of the MA table entries for the MD when the management entity wants to create a new entry in that table An entry cannot be created if a corresponding MD Index does not exist dot1agCfm...

Page 205: ...1agCfmMaMepListIdentifie r 1 3 111 2 802 1 1 8 1 6 3 1 1 1 8191 N A 11 11 7 Peer MEP Database Attributes Table 11 16 Peer MEP Database Attributes Attribute CLI Attribute Name Description SNMP Object I...

Page 206: ...t1agCfmMepDbRMepF ailedOkTime ddd hh mm ss wherein ddd decimal integer representing days it may include arbitrary number of digits hh two digit decimal integer representing hours of day 0 23 mm two di...

Page 207: ...s determined by the value of the dot1agCfmLtrChassisIdSubtyp e object 1 3 111 2 802 1 1 8 1 7 3 1 9 dot1agCfmMepDbChassis Id Hexadecimal string RO Management Address Domain mng addr domain The TDomain...

Page 208: ...smit linktrace message command indicating which LTM s response is going to be returned 1 3 111 2 802 1 1 8 1 7 2 1 1 dot1agCfmLtrSeqNumbe r Integer N A LTR Received TTL rx ttl TTL field value for a re...

Page 209: ...ress MAC address field If the dot1agCfmLtrIngress object contains the value ingNoTlv 0 then the contents of this object are meaningless 1 3 111 2 802 1 1 8 1 7 2 1 14 dot1agCfmLtrIngressMac MAC Addres...

Page 210: ...ned by the value of the dot1agCfmLtrEgressPortIdSub type object If the dot1agCfmLtrEgress object contains the value ergNoTlv 0 then the contents of this object are meaningless 1 3 111 2 802 1 1 8 1 7...

Page 211: ...1 12 Network Object Attributes 11 12 1 Ethernet Interface Attributes This section lists configurable Ethernet Interface attributes Table 11 18 and read only Ethernet Interface attributes Table 11 19 s...

Page 212: ...ngth string Ethernet Type eth type This object identifier represents the operational type of MAU that the administrator has assigned If auto negotiation is not enabled or is not implemented for this M...

Page 213: ...auAutoNegAdminSt atus 1 3 6 1 2 1 26 5 1 1 1 Part of ifMauAutoNegTable 1 3 6 1 2 1 26 5 1 1 Enabled 2 Disabled Enabled Loopback Mode loopback mode Loopback mode operation N A disabled external interna...

Page 214: ...1200 Eth 0 Siklu EH 1200 Eth 1 Siklu EH 1200 Eth 2 MTU Size mtu The size of the largest packet which can be sent received on the interface specified in octets For interfaces that are used for transmit...

Page 215: ...should remain in the Down state if and only if there is a fault condition that prevents the interface from going to the Up state ifOperStatus 1 3 6 1 2 1 2 2 1 8 1 Up Ready to pass packets 2 Down Not...

Page 216: ...t implemented for this MAU then the value that has been assigned in the eth type attribute is used ifMauType 1 3 6 1 2 1 26 2 1 1 3 Part of ifMauTable 1 3 6 1 2 1 26 2 1 For possible values refer to T...

Page 217: ...tgoing Unicast Packets out ucast pkts The number of unicast packets transmitted out of the interface ifOutUcastPkts 1 3 6 1 2 1 2 2 1 17 Discarded Outgoing Packets out discards The number of outbound...

Page 218: ...geBas eBridgeAddress 1 3 111 2 802 1 1 2 1 1 1 1 2 Octet string RO NN NN NN NN NN NN where NN is a hexadecimal number for example 00 AF DD 1E 2D A3 Component Number of Ports num ports The number of po...

Page 219: ...internal interface s1 c1 c2 c3 c4 then the value for this attribute is 0 RO N A Bridge Port PVID pvid The port level VLAN ID that is assigned to untagged frames or Priority Tagged frames received on...

Page 220: ...PDU frames such as MMRP If ingress filtering is enabled on the same port then accepting untagged frames only is not compatible since the combination effectively leads to discarding all frames on the p...

Page 221: ...Frame Counter The counter of the per Q dropped frames drop 0 264 RO 11 12 6 Incoming Queue Object Attributes Table 11 25 Incoming Queue Attributes Attribute CLI Attribute Name Description Syntax Acces...

Page 222: ...t of the MIB ip mask in the form X X X X where X is a decimal number from 0 to 255 for example 255 255 255 0 RC 255 255 255 0 IP Default Router Address The IP address of the default router represented...

Page 223: ...able Attributes Attribute CLI Attribute Name Description CLI Object ID Access Default Component Identifier Used to distinguish between multiple virtual bridge instances within a PB Component identifie...

Page 224: ...are classified as belonging to this VLAN e g MMRP but not MVRP or STP Possible values are 0 264 ieee8021QBridgeTpVlanPortOutFra mes 1 3 111 2 802 1 1 4 1 4 6 1 2 RO n a Per VLAN Dropped Packets drop...

Page 225: ...1 5 1 2 1 4 Yes The C VID will be untagged No The C VID will be tagged RC No Untagged PEP untag pep A flag indicating if this C VID should be carried untagged at the PEP ieee8021PbCVidRegistra tionUn...

Page 226: ...lude the port in its Member Set When disabled the device accepts all incoming frames to the port ieee8021PbEdgePortEna bleIngressFiltering 1 3 111 2 802 1 1 5 1 3 1 5 Enabled Disabled RC Disable d 11...

Page 227: ...ti onRelayVid 1 3 111 2 802 1 1 5 1 1 1 2 1 4094 RC N A Figure 11 3 Bidirectional Definitions of S VID Translation 11 12 13SNMP ifTable Attributes Table 11 32 SNMP ifTable Attributes Attribute CLI Att...

Page 228: ...If ifAdminStatus is not Down and ifOperStatus is Down then a fault condition is presumed to exist on the interface If ifAdminStatus is Down then ifOperStatus will normally also be Down i e there is n...

Page 229: ...2 14Forwarding Data Base FDB Object Attributes Table 11 33 FDB Object Attributes Attribute CLI Attribute Name Description SNMP Object ID Value Access Defaul t Bridge Component ID The component identif...

Page 230: ...s to ieee8021QBridgeFdbT able 1 3 111 2 802 1 1 2 1 2 1 Varies RO N A Dynamic Count num of dynamic The current number of dynamic entries in this Forwarding Database The value of this object is increme...

Page 231: ...s 1 3 111 2 802 1 1 4 1 2 2 1 1 It is an index to ieee8021QBridgeTpFdbT able 1 3 111 2 802 1 1 4 1 2 2 NN NN NN NN NN NN where NN is a hexadecimal number for example 00 AF DD 1E 2D A3 N A N A FDB Port...

Page 232: ...tified here is identical to that of the MIB s ifIndex ipNetToPhysicalIfInd ex 1 3 6 1 2 1 4 35 1 1 1 4 N A 1 ARP IP Address The IP Address that corresponds to the media dependent physical address ipNe...

Page 233: ...g kit installation instructions are also available inside the mounting kit package 2 Remove the protective tape on the antenna feed The 2ft ODU is shipped with External ODU adapter attached 3 Unpack t...

Page 234: ...Installation and User Manual EtherHaul 1200 Page 234...