* These values are provided as a guideline.
1.
As a result of the extremely high signal to noise ratio experienced in pipe propaga-
tion, the blanking may be set to 0.1 m (4"). Normally, a minimum distance of 0.25 m
(10") may be achieved.
2.
Increase Hover level (P839) to 80% to de-sensitize the instrument concerning
deposits or pipe imperfections.
Pipe Inside Diameter
P655 Value (Typical)*
50mm (2”)
0.827
80mm (3”)
0.915
100mm (4”)
0.955
150mm (6”)
0.980
200mm (8”)
0.990