7ML19985CL02
SITRANS LR 300 – INSTRUCTION MANUAL
Page 13
mmm
mm
Inst
allat
ion
Installation
Mounting Location
•
Do not mount in direct sunlight without the use of a sun shield. Refer to Appendix III,
Ambient/Operating Temperature Specification, on page 101 .
Notes:
• Installation shall only be performed by qualified personnel and in accordance with
local governing regulations.
• This product is susceptible to electrostatic shock. Follow proper grounding
procedures.
• Do not use a Ground Fault Interrupt (G.F.I.) with the SITRANS LR 300. The ground path
is used for filtering purposes in conjunction with the universal power supply.
WARNING: This product is designated as a Pressure Accessory per
Directive 97/ 23 / EC and is not intended for use as a safety device.
WARNING: Improper installation may result in loss of process
pressure.
Note: Avoid mounting the unit at the centre:
there is a greater likelihood of false
readings.
Fl
at
Conical
Flat
Parabolic
preferred
undesirable
SITRANS LR 300.book Page 13 Monday, June 10, 2002 7:18 PM