Digital input (Menu item 4.3)
The digital input is available with the device variant 7ME5034-2xxxx (Hart communication and
digital input). You have the following setting options in this menu:
• Function, menu item 4.3.1
By applying an external power supply, you can create a switching input, for example using a
switch (see also Figure 5-12). You have the following possibilities depending on the
configuration:
– Set the measured value to "0" (all outputs and displays are reset to zero and the totalizers
are stopped
– Reset the forwards totalizer
– Reset the reverse totalizer
– Reset the net totalizer
– Reset all totalizers
elektronische
Sicherung
Ri 3k
ext. Versorgung
max. 30 V
ext. Schalter
+
-
4
3
5 V
①
Electronic fuse
②
External switch
③
External supply 11 ... 24 V (max. 30 V)
Figure 8-9
Circuit diagram of digital input
• Signal type, menu item 4.3.2
You can determine the signal type (high-active) with this.
8.6
Function Group Identification
Funct. unit (Menu item 5.1)
You can call or enter device-specific or tag-related data in this menu.
You have the following options:
• TAG (tag number), menu item 5.1.1
• Tag description, menu item 5.1.2
• Message, menu item 5.1.3
Functions
8.6 Function Group Identification
TRANSMAG 2 with MAG 911/E
Operating Instructions, 03/2021, A5E00102775-AC
71
Summary of Contents for SITRANS F TRANSMAG 2
Page 6: ...Table of contents TRANSMAG 2 with MAG 911 E 6 Operating Instructions 03 2021 A5E00102775 AC ...
Page 92: ...Dimension drawings TRANSMAG 2 with MAG 911 E 92 Operating Instructions 03 2021 A5E00102775 AC ...
Page 104: ...Parameters TRANSMAG 2 with MAG 911 E 104 Operating Instructions 03 2021 A5E00102775 AC ...
Page 126: ...Index TRANSMAG 2 with MAG 911 E 126 Operating Instructions 03 2021 A5E00102775 AC ...