Figure 4-1
Correct installation with filled pipes
• Avoid the following installations
– Installation at the highest point in the pipe system
– Installation in vertical pipes with free outlet
Figure 4-2
Wrong installation at high point
Figure 4-3
Correct installation at low point before outlet
Inlet and outlet conditions
To achieve accurate flow measurement it is essential to have straight lengths of inlet and outlet
pipes and a certain distance to pumps and valves.
It is also important to centre the flowmeter in relation to pipe flanges and gaskets.
Installing/mounting
4.2 Sensor installation
TRANSMAG 2 with MAG 911/E
20
Operating Instructions, 03/2021, A5E00102775-AC