![Siemens SINAMICS V50 Operating Instructions Manual Download Page 56](http://html.mh-extra.com/html/siemens/sinamics-v50/sinamics-v50_operating-instructions-manual_385614056.webp)
Parameter description
55
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.
9
Multi-step speed and PLC
Code
Description
Setting range
Default Modify
Modbus
Address
F9.06
Multi-step
freq.7
0.00 ~ Max
frequency
50.00 Hz
о
0A06H
F9.07
PLC running
mode
0: Single cycle
1: Single cycle
and hold final
value
2: Continuous
cycle
2
X
0A07H
F9.08
PLC restarting
mode after
interrupt
0: Restart from
first step
1: Continue
from the step
where the drive
interrupted
0
X
0A08H
F9.09
PLC status
recorded or
not at power
failure
0: Not save
1: Save
0
X
0A09H
F9.10
Time unit
select for each
duration of PLC
processing
0: Second
1: Minute
0
X
0A0AH
F9.11
PLC step1
duration (T1)
0.1 ~3600
20
о
0A0BH
F9.12
PLC step2
duration (T2)
0.0-3600
20
о
0A0CH
F9.13
PLC step3
duration (T3)
0.0-3600
20
о
0A0DH
Summary of Contents for SINAMICS V50