Parameter description
33
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.2 Auxiliary running function group (F2)
Code Description
Setting range
Default
Modify
Modbus
Address
F2.20
Fan control
mode
0: Auto mode
1: Always
Running
0
X
0314H
F2.21
Instant-power-
failure
treatment
0: Disabled
1: Drop frequency
2: Stop directly
0
о
0315H
F2.22
Instant-power-
failure freq.
drop point
210 600V
380V:420
V
о
0316H
220V:230
V
F2.23
Instant-power
failure freq.
drop rate
1-800
400
о
0317H
F2.24
Motor speed
display ratio
0.00 500.0%
100.00%
о
0318H
F2.25
UP/DOWN drop
to minus
frequency
0: Enabled
1: Disable
1
о
0319H
F2.26
ENTER key
function
0: No special
action
1: FWD/REV
switching
2: RUN for
forward;
Enter for reverse;
STOP for stop
3: Jog running
0
о
031AH
F2.27
Freq. resolution
0: 0.01Hz
1: 0.1Hz
0
X
031BH