![Siemens SINAMICS V50 Operating Instructions Manual Download Page 50](http://html.mh-extra.com/html/siemens/sinamics-v50/sinamics-v50_operating-instructions-manual_385614050.webp)
Parameter description
49
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.7
Output terminal
Code
Description
Setting range
Default
Modify
Modbus
Address
23: AI1>F7.16
24:
F7.16<AI1<F7.17
25: Frequency
lower limit arrival
26: Multi-pumps
system auxiliary
pump control
signal
27:
Communication
setting
28: Drive running
time arrival
29: Running in
FWD
30: Running in
REV
31: Instantaneous
power loss
processing
F7.05
Freq. arrival
(FaR) detection
width
0.00 ~ 10.00Hz
2.50Hz
о
0805H
F7.06
Frequency
detection value
1 (FDT1 level)
0.00 ~ 600.0Hz
5.00Hz
о
0806H
F7.07
Freq. detection
lag1 (FDT1-lag)
0.00 ~ 10.00Hz
1.00Hz
о
0807H
F7.08
Frequency
detection value
2 (FDT2 level)
0.00 ~ 320.0Hz
25.00H z
о
0808H
F7.09
Freq. detection
lag2 (FDT2-lag)
0.00 ~ 10.00Hz
1.00Hz
о
0809H
F7.10
Up detection
frequency
0.00 ~ 550.0Hz
50.00H z
о
080AH
F7.11
Down detection
frequency
0.00 ~ 550.0Hz
0.00Hz
о
080BH
F7.12
Torque detection
reference
0.0 ~ 200.0%
100.00 %
о
080CH
Summary of Contents for SINAMICS V50