Parameter description
52
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.7
Output terminal
Code
Description
Setting range
Default
Modify
Modbus
Address
F7.32
Running time
arrival setup
0~65530Min
0
о
0820H
F7.33
Running time
arrival stop
selection
0: Do not stop
1: Stop
0
о
0821H
F7.34
AO1
4mA/2.00v
adjustable
datum
0.0~100.0%
20%
о
0822H
F7.35
AO2
4mA/2.00v
adjustable
datum
0.0~100.0%
20%
о
0823H
F7.36
Digital output
terminal
Pos./Neg. logic
Units: Logic of Y1
terminal
Tens: Logic of Y2
terminal
Hundreds: Logic
of Relay 1
Thousands: Logic
of Relay 2
0000
о
0824H
6.
8
PID Parameters
Code
Description
Setting range
Default Modify Modbus
Address
F8.00
PID setup
channel
selection
0: PID digital
setting (F8.02)
1: AI1
2: AI2
3: Pulse input
4: Serial
communication
0
о
0900H
F8.01
PID feedback
channel
selection
0: AI1
1: AI2
2: Pulse input
3: Serial
communication
4: AI1-AI2
5: AI1+AI2
1
о
0901H