Parameter description
29
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
F0.18 Motor wiring direction
Range: 0 - 1 [0]
The drive output FWD direction might be different from FWD direction of motor. User
can change the motor phases wiring sequence or change this parameter to make
them agree with each other.
0:
Positive sequence
1:
Reversed sequence
F0.19 Acc. time
Range: 0.1 - 3600s [Depend on model]
F0.20 Dec. time
Range: 0.1 - 3600s [Depend on model]
Acceleration time: The time that the drive accelerates from 0Hz to maximum output
frequency (F0.11).
Deceleration time: The time that the drive decelerates from maximum frequency
(F0.11) to 0Hz.
This series drive has defined 4 types of Acc/Dec time. Here, Acc/Dec time 1 is defined,
and Acc/Dec time 2-4 can be defined in F2.03—F2.08. User can select different
Acc/Dec time by external multifunction input terminal. Acc.1/Dec.1 is taken as
default.
Schematic diagram for acceleration/deceleration time