![Siemens SINAMICS V50 Operating Instructions Manual Download Page 42](http://html.mh-extra.com/html/siemens/sinamics-v50/sinamics-v50_operating-instructions-manual_385614042.webp)
Parameter description
41
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.4 V/F Control Parameters
Code
Description
Setting range
Default Modify Modbus
Address
F4.14
V/F oscillation
suppression
0~500
Depends
on model
о
050EH
6.5
Motor Parameters
Code
Description
Setting range
Default
Modify Modbus
Address
F5.00
Motor type
0: Common
asynchronous motor
1: Variable
frequency
asynchronous motor
2: PM motor
0
X
0600H
F5.01
Motor polarity
number
2~56
4
X
0601H
F5.02
Rated power
@0.4~999.9 kW
Depends on
model
о
0602H
F5.03
Rated current
@0.1~999.9 A
Depends on
model
о
0603H
F5.04
Rated speed
@0~24000 RPM
Depends on
model
о
0604H
F5.05
No-load
current
0.1~999.9 A
Depends on
model
о
0605H
F5.06
Stator
resistance R1
0.1~6553.5 mOhm
Depends on
model
о
0606H
F5.07
Leakage
inductive
reactance X
0.001~65.535 mH
Depends on
model
о
0607H
F5.08
Rotor
resistance R2
0.1~6553.5 mOhm
Depends on
model
о
0608H
Summary of Contents for SINAMICS V50