![Siemens SINAMICS V50 Operating Instructions Manual Download Page 49](http://html.mh-extra.com/html/siemens/sinamics-v50/sinamics-v50_operating-instructions-manual_385614049.webp)
Parameter description
48
SINAMICS V50 converter
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
6.7
Output terminal
Code
Description
Setting range
Default
Modify
Modbus
Address
F7.00
DO terminal
output definition
0: NULL
1: RUN
2: Freq.
arrival(FAR)
3: Freq. level
detection 1
(FDT1)
4: Freq. level
detection 2
(FDT2)
5: Freq. detection
when speed-up
6: Freq. detection
when speed-down
7: Zero-speed
running
8: Zero-speed
9: PLC circulation
completion
0
о
0800H
F7.01
Y1 terminal
output selection
1
о
0801H
F7.02
Y2 terminal
output selection
0
о
0802H
F7.03
Relay 1
(TA/TB/TC)
output selection
10: Reserved
11: Ready for
running (RDY)
12: Timing arrival
13: Counting
arrival
14: Reserved
15: Preset torque
value arrival
16: Drive fault
output
17: Under voltage
status output
18: Drive overload
pre-warning
19: Fixed-length
arrived, level
signal
20: PID in
dormancy
21: AI1>AI2
22: AI1<F7.16
16
о
0803H
F7.04
Relay 2
(BRA/BRB/BRC)
output selection
0
о
0804H
Summary of Contents for SINAMICS V50