8.3.4
Installing the 24 V terminal adapter
①
24 V terminal adapter
②
Screw for fixing: SHR, PT-TORX K30-3, 0X16-ST-A2F WN1452 / from EJ
Figure 8-3
Mounted 24 V terminal adapter
You can mount the 24 V terminal adapter on any Adapter Module 600. Open the corresponding
cutout on the protective cover of the DC link using pliers. Clip on the 24 V terminal adapter and
secure it with the screw provided (tightening torque 0.5 Nm / 4.4 lbf in).
The 24 V terminal adapter is suitable for connecting conductor cross-sections of 0.5 mm
2
up to
6 mm
2
(AWG 20 ... 10). The 24 V terminal adapter and associated screw are included in the
scope of delivery of the Line Modules and Control Supply Modules (article number
6SL3162-2AA00-0AA0).
NOTICE
Damage caused by improper mounting of the 24 V terminal adapter
Improper mounting of the 24 V terminal adapter can cause it to be damaged.
● Do not connect or disconnect the 24 V terminal adapter when 24 V is applied.
● Only connect or disconnect the 24 V terminal adapter vertically in relation to the front panel.
Control cabinet design
8.3 24 V DC supply voltage
132
Manual, 06/2019, 6SL3097-5AW00-0BP1
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......