0LQLPXPFXUYH
$
FF
HO
HU
DW
LR
Q
7UDYHUVLQJGLVWDQFH V>P@
D
>P
Vt
@
6,(0(16+\EULG&DEOH
Figure 8-4
Hybrid cable: acceleration as a function of the traversing path (minimum curve)
Table 8-5
Core assignment
Designation/
Color
Meaning
Signal name
Cross-section
[mm
2
(AWG)]
Load
[A]
YE/PK/GN/BU
DRIVE‑CLiQ signal cable (shielded) DRIVE-CLiQ
(1x4xAWG22)/C -
RD
Electronics power supply
P48
2.5 (AWG 12)
10
BU
Ground (GND)
M
2.5 (AWG 12)
10
DCP
DC link v
DCP
4 (AWG 10)
25
DCN
DC link voltage -
DCN
4 (AWG 10)
25
GN/YE
Protective conductor (PE)
PE
4 (AWG 10)
-
Derating characteristic
● If you use the cable at increased ambient temperatures (40 to 55 °C) you must reduce the
DC link current accordingly.
Control cabinet design
8.4 Connection system
136
Manual, 06/2019, 6SL3097-5AW00-0BP1
Summary of Contents for Sinamics S120M