Adapter Module 600
4
4.1
Description
The Adapter Module 600 (AM600) is the interface between the central SINAMICS (Booksize)
components and the S120M integrated in the motor.
The AM600 is implemented in the booksize compact format with 75 mm module width and
opens a line of distributed S120M drives. Correspondingly, the DC link connections, the 24 V
electronics power supply, the status LEDs, the DRIVE-CLiQ sockets, and the terminal strips
are similarly arranged and labeled. The assignment of terminal X21 and the function of the
status LEDs are different from SINAMICS Booksize Compact.
The AM600 feeds the DC link voltage generated in the Line Module into the hybrid cable of the
S120M.
The hybrid cable distributes it to the S120M devices connected in the drive line.
It is possible for several AM600 to be connected to a common infeed unit, and therefore several
lines can be connected. For this, select a suitable Line Module with the necessary infeed power.
NOTICE
Equipment damage due to overload of the 24 V busbar
At maximum load, the AM600 may only be mounted on the right-hand edge of the line-up.
Otherwise, an overload of the 24 V busbar and equipment damage may occur.
● At maximum load, mount the AM600 on the right-hand edge of the line-up.
● Establish the 24 V power supply of the AM600 via an external power supply (e.g. SITOP).
AM600 functions
● Fusing for the hybrid cable conductor protection
The DC link cables are protected against overload using fuses, which can be replaced (also
refer to fuse replacement).
● Generating the 48 V DC electronics power supply for the distributed drive components
The 48 VDC cables are electronically protected against overload and short-circuit.
● Boosting the DRIVE-CLiQ signal using a repeater function (level and signal waveform) and
feeding this into the hybrid cable
General conditions
● Permissible line length per Adapter Module 600: Maximum 100 m.
● Segment length between an Adapter Module 600 and the first node: ≥ 3 m ... ≤ 75 m
Manual, 06/2019, 6SL3097-5AW00-0BP1
55
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......