Connecting the hybrid cable at the S120M of the next line
Table 6-2
Terminal strip X2 (OUT)
Terminal
Signal name
Technical data
1
1 (TXP)
Transmit data +
2
2 (RXP)
Receive data +
3
3 (TXN)
Transmit data -
4
4 (RXN)
Receive data -
5
PE
Potential equalization
6
M
Electronics ground
7
+
48 VDC power supply
8
DCN
DC link voltage - (M600)
9
DCP
DC link v (P600)
-
DQ_SHIELD
Shield
Note
Mounting the hybrid connector
You can screw on the hybrid connector by hand.
● For operation, tighten the hybrid connector with an Allen key (3.0 Nm (26.6 lbf in)).
6.3.3
DRIVE-CLiQ connector
Table 6-3
DRIVE-CLiQ connector X200
Terminal
Signal name
Technical data
1
TXP
Transmit data +
2
TXN
Transmit data -
3
RXP
Receive data +
4
Reserved, do not use
-
5
Reserved, do not use
-
6
RXN
Receive data -
7
Reserved, do not use
-
8
Reserved, do not use
-
A
+ (24 V)
24 VDC power supply
B
GND (0 V)
Electronics ground
DRIVE-CLiQ Extension
6.3 Interface description
112
Manual, 06/2019, 6SL3097-5AW00-0BP1
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......