8.4
Connection system
8.4.1
Power/signal cables
Connection system S120M
The components of the S120M should be connected using DRIVE-CLiQ signal cables and
hybrid cables.
Table 8-3
Components of the S120M connection system
Designation
Article No.
Hybrid cable
6FX8002-7HY..-....
Hybrid Cabinet Bushing
6SL3555-2DA00-0AA0
DRIVE-CLiQ Extension
6SL3555-0AA00-6AB0
DRIVE‑CLiQ cabinet bushing
6SL3066-2DA00-0AA0
DRIVE-CLiQ coupling
6SL3066-2DA00-0AB0
Hybrid cable
The hybrid cable (prefabricated hybrid cable) comprising DRIVE-CLiQ signal cable and signal/
power cables.
Table 8-4
Technical data of hybrid cable 6FX8002-7HY..-....
Technical data
Unit
Value
Maximum permissible number of insertion cycles
50
Bending radii
● Single bends
● Multiple bends
mm
mm
≥60
≥112.5
Tensile strength
● Static
● Dynamic
N/mm
2
N/mm
2
50
20
Properties in the cable carrier
● Minimum bending radius
● Maximum permissible acceleration
1)
● Maximum traversing speed
● Bending cycles
● Permissible horizontal traversing path
● Angle of torsion
mm
m/s
2
m/min
m
Grd
105
50
300
5000000
50
±30
1)
depending on the traversing path (see the diagram below)
Control cabinet design
8.4 Connection system
Manual, 06/2019, 6SL3097-5AW00-0BP1
135
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......