
Press the latch at one side using a slotted screw‐
driver or similar tool – and push out the plug insert
by approx. 2 mm.
Repeat this operation for the second latch.
Remove the plug insert.
Rotate the plug insert through 180°.
Push the plug insert into the housing until it audibly
snaps into place.
8.6.6
Several Control Units and DRIVE-CLiQ Extension
It is possible to use several Control Units and DRIVE-CLiQ Extensions. This should be
configured if more than the maximum permissible number of S120Ms are operated on the same
line.
In this case, the shortest possible Hybrid Cable downstream of the DQE (< 10 m) should be
used for the first axis.
Control cabinet design
8.6 Layout of the components
Manual, 06/2019, 6SL3097-5AW00-0BP1
153
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......