4.9
Technical data
Table 4-6
Technical data AM600
AM600
Unit
6SL3555-2BC10-0AA0
Line system configurations of the infeed
TN/TT line systems with groun‐
ded neutral point or IT line sys‐
tems
Electronic power (input)
Electronics voltage
Electronics current
Current load capacity of the 24 V busbar
V
DC
A
DC
A
DC
24 (-15% ... +20%)
20
20
Line electronics supply (output)
Electronics power supply
Rated voltage (P
out
)
1)
Output current
V
DC
W
A
DC
48
450
10
DC link supply
DC link voltage
Output current (I
n
)
Base load current (I
base
)
S6 current (I
S6
40%)
Peak current (I
max
)
DC link capacitance
Current carrying capacity of the DC link busbar
V
DC
A
rms
A
rms
A
rms
A
rms
μF
A
DC
510 ... 720
25.0
21.3
30.0
50.0
705 ±20%
100
Rated electrical power (for a DC link voltage 600 V
DC
)
kW
14.70
Total power loss (including electronic losses)
W
60
Minimum cable length to the 1st axis
m
≥ 3
Ventilation clearances (above/below)
mm
≥ 80
Maximum length of signal cables
m
30
Maximum cable length for 24 V power supply
m
30
Weight
kg
3.2
1)
Only applies for an electronics input voltage > 26.5 V
Adapter Module 600
4.9 Technical data
74
Manual, 06/2019, 6SL3097-5AW00-0BP1
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......