Effect of thermally insulated/non-insulated mounting without and with gearbox
The heat dissipation of the motor via the flange is reduced by an insulated design or by
mounting gearboxes on motors. The development of heat also changes depending on the
gearbox type.
To avoid thermally overloading motors when using gearboxes, reduce the specified power data
when designing the system (see schematic diagram below).
QRQLQVXODWHG
GHVLJQ
ZLWKJHDUER[
ZLWKRXWJHDUER[
LQVXODWHG
GHVLJQ
Q
0
Figure 5-10
Effect of the mounting conditions on the S1 characteristic
S120M
5.8 Mounting
Manual, 06/2019, 6SL3097-5AW00-0BP1
95
Summary of Contents for Sinamics S120M
Page 2: ......
Page 20: ...Introduction 1 8 General Data Protection Regulation 18 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 56: ...System overview 3 5 System Data 54 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 110: ...S120M 5 11 Motor holding brake 108 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 118: ...DRIVE CLiQ Extension 6 6 Technical data 116 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 126: ...Hybrid Cabinet Bushing 7 6 Technical data 124 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 182: ...Appendix A 2 Documentation overview 180 Manual 06 2019 6SL3097 5AW00 0BP1 ...
Page 185: ......