Accessories
8.4 Control Unit Adapter Kit CUA20
Power Module PM240-2
124
Hardware Installation Manual, 01/2020, A5E33294624B AL
Installing
Note
It is recommended to install the adapter for the Control Unit on the right or left of the Power
Module.
Note
After you finish the installation, properly tie up the excessive part of the connecting cable.
Note
The shield of the STO/safety signal cables should still be connected to the shield plate of the
Control Unit when using the Control Unit Adapter Kit CUA20.
Technical specifications
Net weight
1032.8 g
Operating temperature
- 20 °C ... 60 °C
Shock and vibration
•
Transportation: 1M2 according to EN 60721-3-2
•
Operation: 3M1 according to EN 60721-3-3
Protection against chemical substances
2C2 according to EN 60721-3-2
Standards and directives
CE, UL, TUV, EAC, RCM
Summary of Contents for SINAMICS G120