
Commissioning
4.5 Commissioning with STARTER
Inverter with CU240B-2 and CU240E-2 Control Units
76
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
If the USB-COM emulation is assigned to an address higher than COM7, open the properties
window by double-clicking on the interface. There you will find the "Advanced" button under
the "Port settings" tab.
A click on this button opens the extended properties in which you can assign the COM
connection number an address < 8 via a selection box. If all of the COM1 … COM8
addresses are assigned, then select one of these addresses anyway and confirm the
following message with "Yes". Please note the COM interface that you have assigned as you
will require it in a subsequent installation step.