Description
2.3 Power Module
Inverter with CU240B-2 and CU240E-2 Control Units
28
Operating Instructions, 07/2010, FW 4.3.2, A5E02299792B AA
PM250-2, 3AC 400V - power units capable of energy recovery
Power range (LO)
0.55 kW
… 3 kW
4 kW
… 7.5 kW
---
---
---
---
---
With integr. line filter, Class A
○/●
○/●
---
---
---
---
---
PM260, 3AC 690V - power units capable of energy recovery
Power range (LO)
---
---
---
11 kW
… 18.5 k
W
---
30 kW
… 55 kW
---
With integr. line filter, Class A
---
---
---
○/●
---
○/●
---
With integr. sine-wave filter
---
---
---
●
---
●
---
● = Feature available; ○ = Feature not available; ◑ = Feature available, modified
1) PM240 Power Modules, 110 kW and higher, are only available without an integrated class A filter. Instead, an optional
class A line filter for lateral mounting is available.
2) The Power Module PM240 FSGX is delivered without braking chopper, but is prepared for installation of an optional
braking chopper.
Figure 2-3
PushThrough Power Modules, PM240-2, PM250-2
Table 2- 2
PushThrough Power Modules, PM240-2, PM250-2
Frame size
FSA
FSB
FSC
FSD
FSE
FSF
PM240, 3AC 400V - power units with integrated braking chopper
2)
Power range (LO)
2.2 kW
… 3 kW
---
---
---
---
---
With integr. line filter, Class A
○/●
---
---
---
---
---
PM250, 3AC 400V - power units capable of energy recovery
Power range (LO)
3 kW
7.5 kW
---
---
---
---