This permits a project download using remote maintenance or series commissioning.
Note
Note the SIMOTION version
The SIMOTION version on the target device must exactly match the version of the device on
which the backup was created.
After the upload of a SIMOTION project into the SIMOTION P320-4 (SIMOTION device
update), the time stamps in the user data and the SIMOTION SCOUT project are different.
The project is shown as inconsistent in SIMOTION SCOUT.
The consistency can be established via a project download or a download of the HW Config
in the SIMOTION SCOUT.
8VHUGDWD
:HEEURZVHU
(WKHUQHW
HJ
86%VWLFN
3*KDUGGLVN
HWF
([WHUQDOPHPRU\
6,027,213
)LUPZDUH
2SHUDWLQJV\VWHP
66'
&)DVWFDUG
6WRUDJHPHGLXP
LQWHUQDO
5HWDLQGDWD
.HUQHOGDWD
&XUUHQWGDWD
%DFNXSV
6WRUDJHPHGLXP
H[WHUQDO
&)DVWFDUG
6,027,213
6WRUDJHPHGLD
(QJLQHHULQJV\VWHP
6,027,213
65$0
5$0
Figure 10-5 SIMOTION SCOUT download (ZIP file)
Download of the project data process (ZIP file)
1. Save the data via SIMOTION SCOUT, menu Edit > Load to file system ... (option Save
compressed), on the file system of your programming device.
2. Transfer the ZIP file via the web browser and the project download of SIMOTION IT:
Manage Config > [Login dialog] > Device Update > Send new update data (*.ZIP)
3. The unpacking and the import of the data into the user data on the external CFast card is
performed automatically.
Commissioning (software)
10.8 Data storage concept
SIMOTION P320-4 E / P320-4 S
Commissioning and Hardware Installation Manual, 11/2016
163