1 Technical Description, Installation Guidelines, Operation
13
IE/AS
−
INTERFACE LINK PN IO
as of hardware version 1, as of firmware version V2.0
Release 08/2018
C79000
−
G8976
−
C216
−
03
1.2
Uses of the Module
PROFINET IO Device and AS-Interface Master
The IE/AS-i LINK is both a PROFINET IO device and AS-Interface master:
S
IE/AS-i LINK connects the actuator-sensor interface with PROFINET IO.
S
Using the IE/AS-i LINK module, you can access the inputs and outputs of the
AS-i slaves from PROFINET IO Depending on the slave type, you can access
binary values and / or analog values.
The following AS-i slaves can be used:
−
Standard slaves / analog slaves / combi slaves
−
Slaves with the extended addressing mode
−
Slaves with data transfer mechanisms complying with the AS-i specification
V3.0
−
Combined Transaction Type (CTT) 1
−
5.
Figure 1-1
Example of a System Configuration with the IE/AS-INTERFACE LINK PN IO
(double
master)
Power
supply
Power
supply
When IE/AS-i Link PN IO is used
as double master
Slave
Slave
Safe
slave with
EMERGENCY-
STOP
Safe
slave with
EMERGENCY-
STOP
Laser
scanner
3RA2 load
feeders
IE/AS-i Link PN IO
ET 200pro
ET 200SP
IK10_4001
7c
SCALANCE
XC208
Industrial Ethernet
PROFINET
AS-Interface
AS-Interface
MSS
ASIsafe
MSS
ASIsafe
SIMATIC
Software Controller
SIMATIC HMI
SIMATIC/
SIMOTION