EWA 4NEB 812 6119-02b
Length of the SINEC L2 bus cable
The following values apply for the SINEC L2 bus cable in accordance
with the baud rate on the bus when configuring the ET 200C.
Table 1-2
Length of the SINEC L2 Bus Cable in Accordance with the Baud Rate on
the SINEC L2-DP Bus
Baud rate
Max. length of bus cable
< 500 kbaud
500 m/segment
500 kbaud
400 m/segment
1500 kbaud
200 m/segment
> 1500 kbaud
100 m/segment