4-42
ET 200C Distributed I/O Station
EWA 4NEB 812 6119-02b
4.3.10 Wiring of the External Power Supply to the PS Connector
An external power supply must be connected to the power supply connector.
To connect the external power supply you will require
6-pin circular socket
and
Flexible 3-core Cu cables:
–
with a minimum core cross-section of 0.75 mm
2
(AWG 18) and a
diameter of 6 to 10 mm.
Connect the circular socket in accordance with the following pin assignment:
Table 4-18
Pin Assignment of the External Power Supply
Pin
Power supply
1
PE
2
P 24 V
3
M 24 V
4
free
5
free
6
free
Connections which are not required must be sealed using the enclosed metal
caps.
Introduction
Connecting
External Power
Supply
Sealing of Unused
Connections
Mechanical and Electrical Installation
Summary of Contents for SIMATIC ET 200C
Page 18: ...xviii ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Contents ...
Page 26: ...1 8 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Configuration ...
Page 44: ...2 18 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b ET 200C Configuration Options ...
Page 68: ...3 24 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b ET 200C Components ...
Page 202: ...10 4 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b General Technical Specifications ...
Page 226: ...11 24 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Digital Modules ...
Page 270: ...12 44 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Analog Modules ...
Page 280: ...13 10 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Other ET 200C Components ...
Page 310: ...C 4 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Safety Related Guidelines ...
Page 318: ...Glossary 8 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Glossary ...
Page 324: ...Index 6 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Index ...