ET 200C Distributed I/O Station
EWA 4NEB 812 6119-02b
You parameterize the ET 200C; AO 4
12 Bit with the aid of the
COM ET 200 Windows parameterization software.
Parameterization of the ET 200C; AO 4
12 Bit with COM ET 200
Windows is described in detail in the Help system integrated in the
COM ET 200 Windows program.
The manual entitled ET 200 Distributed I/O System
(Order No. 6ES5 998-3ES12) contains detailed descriptions of how to use
COM ET 200 Windows.
All the parameters for the ET 200C; AO 4
12 Bit are described in the
table below:
Table 12-28 Parameters for ET 200C Analog Output Module; AO 4
12 Bit
Byte
1
Bit
Parameter
Explanation
Range of values
08
0
Enable diagnostics CH 0
Enable diagnostics messages by
channel groups
disable
bl
1
Enable diagnostics CH 1
channel groups
enable
2
Enable diagnostics CH 2
3
Enable diagnostics CH 3
15
6
Enable diagnostics alarm
Enable diagnostics alarm of
module
disable
enable
16
0
Type of substitute value, CH 0
Channel by channel definition
of substitute value output on
Substitute value
l t
l
1
Type of substitute value, CH 1
of substitute value output on
error
last value
2
Type of substitute value, CH 2
error
3
Type of substitute value, CH 3
17
0 ... 7
Output type / output range CH 0
Channel by channel selection of
output range
Output range
"
10 V
O
0
10 V
18
0 ... 7
Output type / output range CH 1
output range
p
g
Output range 0 ... 10 V
Output range 0 ... 20 mA
19
0 ... 7
Output type / output range CH 2
Output range 0 ... 20 mA
Output range 4 ... 20 mA
O
20
A
20
0 ... 7
Output type / output range CH 3
Output range
"
20 mA
21
0 ... 7
Substitute value CH 0
Channel by channel input of
substitute value
0
32768
32767
23
0 ... 7
Substitute value CH 1
substitute value
(if communication is
i
d
l
i
i
–32768 ... 32767
25
0 ... 7
Substitute value CH 2
interrupted, value input is output
as substitute value –
27
0 ... 7
Substitute value CH 3
as substitute value
see Table 12-29)
34
2
Measured value presentation
Present measured value for
master system S5 or S7
S5
S7
: Default setting in parameterization telegram
1
Byte address in parameterization telegram of slave
Parameterization
Where to Look
Analog Modules
Summary of Contents for SIMATIC ET 200C
Page 18: ...xviii ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Contents ...
Page 26: ...1 8 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Configuration ...
Page 44: ...2 18 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b ET 200C Configuration Options ...
Page 68: ...3 24 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b ET 200C Components ...
Page 202: ...10 4 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b General Technical Specifications ...
Page 226: ...11 24 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Digital Modules ...
Page 270: ...12 44 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Analog Modules ...
Page 280: ...13 10 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Other ET 200C Components ...
Page 310: ...C 4 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Safety Related Guidelines ...
Page 318: ...Glossary 8 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Glossary ...
Page 324: ...Index 6 ET 200C Distributed I O Station EWA 4NEB 812 6119 02b Index ...