UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
116 A50010-Y3-C150-2-7619
Command Mode
Description
snmp alarm-severity adva-if-trans-fault
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sends alarm notification with the sever-
ity when ADVA informs to fail to transmit
the packets.
snmp alarm-severity adva-psu-fail
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sends alarm notification with the sever-
ity when ADVA informs there’s any
problem on the power.
snmp alarm-severity adva-temperature
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sends alarm notification with the sever-
ity when ADVA informs there is any
problem in temperature.
snmp alarm-severity adva-voltage-high
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sends alarm notification with the sever-
ity when ADVA informs the voltage is
high.
snmp alarm-severity adva-voltage-low
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sends alarm notification with the sever-
ity when ADVA informs the voltage is
low.
If you want to clear a configured ADVA alarm prioirity, use the following command.
Command Mode
Description
no snmp alarm-severity adva-fan-fail
no snmp alarm-severity adva-if-misconfig
no snmp alarm-severity adva-if-opt-thres
no snmp alarm-severity adva-if-rcv-fail
no snmp alarm-severity adva-if-sfp-mismatch
no snmp alarm-severity adva-if-trans-fault
no snmp alarm-severity adva-psu-fail
no snmp alarm-severity adva-temperature
no snmp alarm-severity adva-voltage-high
no snmp alarm-severity adva-voltage-low
Global
Clears a configured ADVA alarm
prioirity.
7.1.9.6 ERP
Alarm
Severity
To configure a severity of alarms for ERP status, use the following command.
Command Mode
Description
snmp alarm-severity erp-domain-lotp
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sends alarm notification with the sever-
ity when no test packet has been re-
ceived within 3 test packet intervals in
ERP mechanism.
snmp alarm-severity erp-domain-multi-rm
{
critical
|
major
|
minor
|
warning
|
intermedi-
ate
}
Global
Sends alarm notification with the sever-
ity when a Multiple RM node is created.