UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
374 A50010-Y3-C150-2-7619
##############################################################################
##############################################################################
############################################################
13661792 bytes download OK.
SWITCH#
show flash
Flash Information(Bytes)
Area
total
used
free
--------------------------------------------------------------
OS1(default)(running)
16777216
13661822
3115394
3.18 #1009
OS2
16777216
13661428
3115788
3.12 #1008
CONFIG
4194304
663552
3530752
--------------------------------------------------------------
Total
37748736
27986802
9761934
SWITCH#
reload
Do you want to save the system configuration? [y/n]
y
Do you want to reload the system? [y/n]
y
Broadcast message from admin (ttyp0) (Fri Aug 18 15:15:41 2006 +0000):
The system is going down for reboot NOW!
11.2
Boot Mode Upgrade
In case that you cannot upgrade the system software with the general upgrade procedure,
you can upgrade it with the boot mode upgrade procedure. Before the boot mode up-
grade, please keep in mind the following restrictions.
•
A terminal must be connected to the system via the console interface. To open the
boot mode, you should press <
S
> key when the boot logo is shown up.
•
The boot mode upgrade supports TFTP only. You must set up TFTP server before
upgrading the system software in the boot mode.
•
In the boot mode, the only interface you can use is MGMT interface. So the system
must be connected to the network via the MGMT interface.
•
All you configures in the boot mode is limited to the boot mode only!
To upgrade the system software in the boot mode, perform the following step-by-step in-
struction.
Step 1
To open the boot mode, press <
S
> key when the boot logo is shown up.
************************************************************
*
*
* Boot Loader Version 4.76
*
* Siemens AG
*
*
*
************************************************************
Press 's' key to go to Boot Mode: 0
Boot>
!