User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 49
4.1.8.2
Auto System Rebooting
The hiD 6615 S223/S323 reboots the system according to user’s configuration. There are
two basises for system rebooting. These are CPU and memory. CPU is rebooted in case
CPU Load or Interrupt Load continues for the configured time. Memory is automatically
rebooted in case memory low occurs as the configured times.
To enable auto system rebooting function, use the following command.
Command Mode
Description
auto-reset cpu
<50-100> <1-100>
TIME
Configure to reboot the system automatically in case
an average of CPU or interrupt load exceeds the con-
figured value during the user-defined time.
50-100: average of CPU load per 1 minute
1-100: average of interrupt load
TIME: minute
auto-reset memory
<1-120> <1-
10>
Configure to reboot the system automatically in case
memory low occurs as the configured value.
1-120: time of memory low
1-10: count of memory low(The default is 5)
no auto-reset
{
cpu
|
memory
}
Bridge
Disables auto system rebooting.
To show auto system rebooting configuration, use the following command.
Command Mode
Description
show auto-reset
{
cpu
|
memory
}
Global/
Bridge
Shows a configuration of auto-rebooting function.
The following is an example of configuring auto-restarting function in case CPU load or
Interrupt load maintains over 70% during 60 seconds and viewing the configuration.
SWITCH(config)# SWITCH(bridge)#
auto-reset cpu
70 70 1
SWITCH(bridge)#
show auto-reset cpu
------------------------------
Auto-Reset Configuration(CPU)
------------------------------
auto-reset: on
cpu load: 70
interrupt load: 70
continuation time: 1
SWITCH(bridge)#
4.2 System
Authentication
For the enhanced system security, the hiD 6615 S223/S323 provides two authentication
methods to access the switch using Remote Authentication Dial-In User Service (RA-
DIUS) and Terminal Access Controller Access Control System Plus ().