UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
82 A50010-Y3-C150-2-7619
Step 4
To delete and modify the configuration, use the following command.
Command Mode
Description
mirror disable
Deactivate monitoring.
mirror del
PORTS
[
ingress
|
egress
]
Bridge
Delete a port from the mirrored ports.
Step 5
To disable monitoring function, use the following command.
Command Mode
Description
no mirror monitor
Bridge
Disable port mirroring function.
The following is an example of configuring port mirroring with a port.
Step 1
Connect a motoring PC to the monitor port of the switch.
Step 2
Enable mirroring function.
SWITCH(bridge)#
mirror enable
SWITCH(bridge)#
Step 3
Configure the monitor port 1 and mirroring port 2, 3, 4 and 5.
SWITCH(bridge)#
mirror monitor
1
SWITCH(bridge)#
mirror add
2
SWITCH(bridge)#
mirror add
3-5
SWITCH(bridge)#
Step 4
Check the configuration.
SWITCH(bridge)#
show mirror
Mirroring enabled
Monitor port =
-----------------------------------
| 1
|123456789012
-----------------------------------
Ingress Mirrored Ports|............
Egress Mirrored Ports|............
SWITCH(bridge)#