Meter
MAG 8000 Standard
(7ME6810)
MAG 8000 CT
(7ME6820)
Custody transfer approval
NMI
OIML R49:2013
OIML R 49 MAA
MI-001 (DK-0200-MI001-011)
NMI
Conformity
-
CEN EN 14154
ISO 4064
PED
2014/68/EU
EMC
EN 61326-1
For further features, see "Features" (Page 163).
10.2
Sensor
Technical specifications
Sensor
MAG 8000
(7ME6810)
MAG 8000 CT
(7ME6820)
Size, flange and pressure
range
EN 1092-1
(DIN 2501)
DN 25, DN 40, DN 350 - DN 600: PN
40
DN 50 to 150: PN 16
DN 200 to 1200: PN 10 or PN 16
DN 350 - DN 600: PN 25
DN 50 to 600: PN 16
ANSI 16.5
Class 150 lb
1" to 24": 20 bar (290 psi)
2" to 24": 16 bar (232 psi)
AWWA C-207
28" to 48": PN 10
-
AS 4087
DN 50 to 1200: PN 14
DN 50 to 600: PN 16
AS 2091-1
Table D
-
-
AS 2191
Table E
Max. excitation frequency
Basic version
Battery-pow‐
ered
1/15 Hz for sensor size
DN 25 to 150 (1" to 6")
1/30 Hz for sensor size
DN 200 to 600 (8" to 24")
1/60 Hz for sensor size
DN 700 to 1200 (28" to 48")
1/15 Hz for sensor size
DN 50 to 150 (1" to 6")
1/30 Hz for sensor size
DN 200 to 600 (9" to 24")
Mains-powered
6.25 Hz for sensor size
DN 25 to 150 (1" to 6")
3.125 Hz for sensor size
DN 200 to 600 (8" to 24")
1.5625 Hz for sensor size
DN 700 to 1200 (28" to 48")
6.25 Hz for sensor size
DN 25 to 150 (1" to 6")
3.125 Hz for sensor size
DN 200 to 600 (8" to 24")
Technical data
10.2 Sensor
SITRANS FM MAG 8000
94
Operating Instructions, 03/2020, A5E03071515-AH