MAG 8000 CT is approved with OIML R49:2013 and MID for the following installations:
● DN 50 to DN 300 with 0x D
i
of straight pipe upstream to the sensor and 0x D
i
of straight pipe
downstream from the sensor.
● DN 350 to DN 600 with 3x D
i
of straight pipe upstream to the sensor and 3x D
i
of straight pipe
downstream from the sensor.
For optimal measurement performance, it is recommended to follow the installation guidelines
for the MAG 8000 standard water meter.
MAG 8000
(recommended)
MAG 8000 CT
DN 50 to DN 300
MAG 8000 CT
DN 350 to DN 600
①
Minimum straight inlet pipe length
5x D
i
0x D
i
3x D
i
②
Minimum straight outlet pipe length
3x D
i
0x D
i
3x D
i
Sensor must be completely full of liquid
Installing/Mounting
4.1 Sensor installation
SITRANS FM MAG 8000
Operating Instructions, 03/2020, A5E03071515-AH
19