6.6
Data protection
Using hardware key
A hardware key is installed in the HL hole to change protected parameters. The HL
hole is located in the front of the PCB board behind the battery.
MAG 8000 Standard / MAG 8000 CT)
Parameter no. Parameter name
-
New Password
5
Sensor tube diameter
7
Meter No.
8
Totalizer unit
9
Flow unit
10
Qn (Q3)
300
Totalizer unit factor
301
Flow unit factor
302
Pipe size
321
Calibration date
323
Calibration factor
325
Sensor offset
332
Max. sensor excitation frequency
Additional protected parameters (MAG 8000 CT)
Parameter no. Parameter name
101
Totalizer 1
102
Totalizer 2
103
Net totalizer (since FW 3.11)
303
Operation excitation frequency
305
Decimal point place
310
Flow direction totalizer 1
312
Flow direction totalizer 2
327
Adjustment factor
328
Low flow cut-off
332
Empty pipe impedance
420
Device Communication Address
550
Coil current active
551
Fix flow mode active
Commissioning
6.6 Data protection
SITRANS FM MAG 8000
58
Operating Instructions, 03/2020, A5E03071515-AH