Size
50
(2")
65
(2½")
80
(3")
100
(4")
125
(5")
150
(6")
200
(8")
250
(10")
300
(12")
350
(14")
400
(16")
450
(18")
500
(20")
600
(24")
"R" Q
3
/Q1
250
Q4 [m
3
/h] 78.7
5
125
200 312.5 500
787.5 1250
2000
2000
-
-
-
-
-
Q3 [m
3
/h] 63
100
160 250
400
630
1000
1600
1600
-
-
-
-
-
Q2 [m
3
/h] 0.40
3
0.64
1.02
4
1.6
2.56
4.032 6.4
10.24 10.24 -
-
-
-
-
Q1 [m
3
/h] 0.25
2
0.4
0.64 1
1.6
2.52
4
6.4
6.4
-
-
-
-
-
Operating Conditions
Environment class
E2, M1
Climatic class
-25…55 °C, condensing, closed
Verification tolerance
±5 % Q
1
< Q < Q
2
±2 % Q
2
≤ Q ≤ Q
4
Unit of measurement
Cubic meters
Temperature
T30 (0.1 °C - 30 °C) / tested up to T50 according to OIML R49:2013
Pressure
PN ≔ 16 bar or PN ≔ 10 bar or PN ≔ 6 bar
Power supply
3.6 V Lithium Battery, 12 - 24 VAC/VDC, 115 - 230 VAC
Compact/Remote
Max. 30 m cable
10.11
The effect of temperature MAG 8000 (7ME6810) and MAG 8000 CT
(7ME6820)
Metric (Pressures in bar)
Flange spec.
Flange rating
Temperature °C
0
10
50
70
Sizes 25 mm, 40 mm and > 300 mm
EN 1092-1
PN 10
10.0
10.0
9.7
9.4
PN 16
16.0
16.0
15.5
15.1
PN 40
40.0
40.0
38.7
37.7
ANSI 16.5
150 lb
19.7
19.7
19.3
18.0
Sizes 50 mm to 300 mm
EN 1092-1
PN 10
10.0
10.0
10.0
8.2
PN 16
10.0
16.0
16.0
13.2
ANSI 16.5
150 lb
10.0
19.7
19.7
16.2
Technical data
10.11 The effect of temperature MAG 8000 (7ME6810) and MAG 8000 CT (7ME6820)
SITRANS FM MAG 8000
108
Operating Instructions, 03/2020, A5E03071515-AH
Summary of Contents for 7ME6810
Page 16: ...Description 3 4 Benefits SITRANS FM MAG 8000 16 Operating Instructions 03 2020 A5E03071515 AH ...
Page 140: ...Unit conversion table SITRANS FM MAG 8000 140 Operating Instructions 03 2020 A5E03071515 AH ...
Page 168: ...Features SITRANS FM MAG 8000 168 Operating Instructions 03 2020 A5E03071515 AH ...