Dobot Magician User Guide
Dobot Magician Homing Operation
Issue V1.9.0 (2020-07-23)
User Guide
Copyright © Yuejiang Technology Co., Ltd.
142
Now, demos of level output, level input, and PWM output are given below.
Level Output
Normally, air pump can be controlled by the I/O interfaces. The I/O
11
controls its intake (High
level) and outtake (Low level) and the I/O
16
controls its start-stop. Table 5.20 lists the multiplexed
descriptions of I/O
11
and I/O
16
.
Table 5.20 Multiplexed I/O description
I/O addressing
Voltage
Level Output
PWM
Level Input
ADC
11
3.3V
√
√
-
-
16
12V
√
-
-
-
The I/O
11
and I/O
16
are located at the peripheral interface of the base, as shown in Figure
Figure 5.173 Peripheral Interface on the base
Prerequisites
The air pump has been connected to Dobot Magician. For details, please see
Dobot Magician has been powered on.
Dobot Magician has been connected to DobotStudio successfully.
Procedure