UP-5900VS
CIRCUIT DESCRIPTION
5 – 53
For details of control codes, refer to “UP-P20DP Command Specifications.”
(4) Connector specifications
RJ45 (for UP-P20DP)
Connector (for UP-I20DP)
Note: The UP-P20DP and the UP-I20DP cannot be used at the same
time because of limited power capacity.
25. DRAWER
25-1. OUTLINES
Operations of 2ch are allowed for the ER-03DW and the ER-04DW.
However, simultaneous drive is not allowed.
Drawer drive time by PSC2 = 45ms
Time from PSC2 drive to sense becoming effective: Sense effective
time = 200ms
When two drawers are opened continuously, the output interval of
drawer open commands is 50ms or more.
The number of times of drawer open is limited to max. 15 times/min due
to the power specification.
Drive shutdown function by PSC2 service interruption detection.
25-2. DRAWER CONTROL
Drawer Control Register (PSC+0Ah)=18Ah
25-3. TIMING CHART
US MD3
Horizontal Scroll Mode select
1Fh 03h
ESC & s n m [a [p] sua] (m-n+1)
Download text definition
1Bh 26h
s n m [a [p] sua] (m-n+1)
ESC ? n
Download text delete
1Bh 3Fh
n
ESC % n
Download text set select/cancel
1Bh 25h
n
ESC W n m x1 y1 x2 y2
Window range select/cancel
1Bh 57h
n m x1 y1 x2 y2
US :
Macro content definition start and end
1Fh 3Ah
US ^ n m
Macro process execution
1Fh 5Eh
n m
US @
Self Test execution
1Fh 40h
US v n
Status check by DTR signal
1Fh 76h
n
US T n h m
Counter (Time) setup and display
1Fh 54h
n h m
US U
Counter (Time) display
1Fh 55h
US # n m
Annunciater display select
1Fh 23h
n m
SLP
Sleep Mode execution
06h
n
DC
Select position display blinking
17h
n m s
US . n
Period display select
1Fh 2Eh
n
US , n
Comma display select
1Fh 2Ch
n
US ; n
(Comma) display select
1Fh 3Bh
n
Command
Function
Code
Pin No.
Signal
Function
I/O
1
+5V
+5V
—
2
ER
SLP control(Data terminal Ready)
O
3
SD
Send Data
O
4
SG
Signal Ground
—
5
SG
Signal Ground
—
6
(NC)
(Not Connected)
7
DR
Data set Ready
I
8
+5V
+5V
—
Pin No.
Signal
Function
I/O
1
SG
Signal Ground
—
2
SG
Signal Ground
—
3
SD
Send Data
O
4
ER
SLP control(Data terminal Ready)
O
5
DR
Data set Ready
I
6
+5V
+5V
—
7
+5V
+5V
—
DCR
b7
b6
b5
b4
b3
b2
b1
b0
Read
DS
0
0
0
1
1
DR1
DR0
Write
u
u
u
u
1
1
DR1
DR0
bit7 :
Drawer open Sensor input port (Read Only)
DS=0 : All of drawers are closed.
DS=1 :One of drawers is opened.
bit6-4 :not use
bit3 :
Drawer solenoid drive port 3 (not use)
bit2 :
Drawer solenoid drive port 2 (not use)
bit1 :
Drawer solenoid drive port 1
DR1=0 : Solenoid ON
DR1=1 : Solenoid OFF
bit0 :
Drawer solenoid drive port 0
DR0=0: Solenoid ON
DR0=1: Solenoid OFF
Solenoid ON
DRO-DR1
DS
45.017ms
Max. 200ms
Max. 50us
Drawer Open complete
Manual Drawer close
Max. 50us
Detection delay