- 33 -
Auto Zero Range setting
F05 05
00
∫
99
Within the “Auto Zero” range, weighing part is steady, indicator will
display current weight as “Zero”
If the weighing part is not “Steady”, indicator will display current weight.
(Auto Zero Range : ± Set value + weight unit)
※
Using this function, you can get the Zero value without pressing “Zero” key, when there is remained
material on the scale within Auto Zero Range.
Example) Max. Capacity : 10kg, Digit : 0.02kg, F005-30 setting,
Under this setting, Indicator will display “Zero” automatically, when the weight is within ± 0.30kg(Set
value + weight unit) and Steady.
Digital Filter setting
F06 23 AB
A : Frequency Filter setting value (0~3)
(0 : about 200Hz/sec, 3 : about 500Hz/sec)
B : Buffer Filter setting value (1~9)
If “B” set value is fixed,
“A” set value is large, the
indicator will response
more sensitive.
※
This function is related with “Zero Tracking Compensation Range setting(F04)”
※
If there is strong vibration near weighing part, please set “A” with large value.(If the “B” set value is
fixed.)
Zero /Tare key Operation mode selection
●
0
Activate
when
“Steady” condition, only
F07
1
Always
activated
Motion Band Range
Steady
Range
F03-01
Motion Band Range
Zero
F03-01
+0.30kg