- 36 -
SUB/GRAND Total Display mode selection
●
0
Display Accumulated weighing count and weight of current P/N
(SUB TOTAL DATA Display)
F15
1
Display Accumulated weighing count and weight of all P/N
(GRAND TOTAL DATA Display)
※
The Sub/Grand Total data will be displayed on Sub-display windows, when
and
key input.
※
Max. Display value of Accumulated weighing Count is “999,999”, and over this value, count will be
return to “000,000”.
※
Max. Display value of Accumulated weight is “2,147,483,647”, and over this value, accumulated
weight will be return to “0,000,000,000”.
Minus(-) symbol display selection
●
0
Display (-) symbol on the display
F16
1
Not
use
“NEAR ZERO” relay output mode selection
●
0
Display weight is Zero(Including “TARE” Zero)
Æ
Near Zero relay
output
F17
1
Only Gross Zero(Net TARE)
Æ
Near Zero relay output
※
Under F17-01 setting, even if the TARE is set and display weight is Zero, there is no NEAR Zero
relay output. – Only when the Net weight is Zero, there is Near Zero relay output.
Equipment No. setting
F18 01
01
∫
99
Equipment No. setting with No. key.
(01 ~99 settable)