printing purpose. So the following “F-functions, F35, F36, F37, F38” will not be activated.
So, ignore the F35, 36, 37, 38 settings.
Under Command Mode setting(F32-01), F33, and F34 function will be activated.
※
If you want to fix “Serial Port 1.” for Command mode, and you also want to data transference or
print purpose, you have to add optional serial port and set up for data transference or print through
optional serial port, Please refer F65, 66, 67, 68.
Print port selection (Under F32-01 setting, only)
●
0
Same port as using for Command Mode.
F33
1
The other port.
※
Through this function, you can selection print port, which will be used for print, when indicator takes
a “Print Command” from P.C. If you choose F33-00, the print data will be transfer to P.C with print
format. If you choose the other port, the print data will be transfer through the other port – option
Port(Com. Port 2)
If you set F33-01, but you just connect with another P.C, you can take print data with print format
though the another P.C In this case, the transferred data format is same as print format, not a data
format(please refer “Print Interface section”)
“Check-Sum” detection selection (Under F32-01 setting, only)
●
0
Check-Sum data will not be included on transferred data.
F34
1
Check-Sum data will be included on transferred data.
Serial Port Application Selection (Under F32-00 setting, only)
●
0
DATA
Transference
purpose
F35
1
Printing purpose (Serial Printer)
※
Under “DATA Transference” Mode(F35-00), F36,37 function will be activated.
Under “Print Purpose” Mode(F35-01), F38 function will be activated.
DATA Transference Mode selection (Under F32-00, F35-00 setting, only)
●
0
Stream Mode : Weighing Data will be transferred continuously.
1
Finish Mode : When Finish Relay output, only 1 time transferred.
F36
2
Manual Mode : When “Print” key input, 1 time transferred.