HIGH / LOW Letter display selection (On Sub Display window)
●
0
Letter
not
use
F54
1
Letter will use (High relay : HI / Under relay : LO)
Auto HOLD Tracking Function selection (Under F21-02 mode)
●
0
Auto HOLD Tracking not use
F55
1
Auto HOLD Tracking use
※
When the Weight will be increased, indicator will set
“
HOLD
”
automatically, and weight will be
decreased, Indicator will reset the HOLD.
The Standard point of this HOLD set or reset is
“
Empty Range
”
.
※
If the F55-01 setting, you must set “F52-00”.
“
EMPTY
”
Checking selection
●
0
EMPTY
check
F56
1
EMPTY
not
check
※
This function will work under
“
F21-01
”
setting, only.
Under “F56-00” setting : After having “Sensor” input, indicator will check the “EMPTY” range and
current weight, if the current weight is less than “Empty” range, indicator
will not start measuring.
Under “F56-01” setting : After having “Sensor” input, indicator will start measuring, whatever current
weight is.
Communication Interval Setting
●
0
Fast Speed (The interval is short)
F57
1
Low Speed (The interval is long)
※
This setting is for “Communication Interval” with P.C or PLC.
If the “Fast Speed” interval is too fast to meet with P.C or PLC, please set “Low Speed” interval.