- 48 -
Minus(-) symbol Print selection
●
0
Print minus(-) symbol, if the weight is minus(-).
F49
1
Ignore minus(-) symbol
Parallel Print Port selection
●
0
Parallel Port is not installed.
1
Share Standard Serial Port.
F50
2
Share Optional Serial Port.
※
If you install “Print interface option(Centronics Parallel), you have to choose, which port you will
use for print data transference to “Print Interface”.
If you installed “Print interface”, but you didn’t choose the port, you can not print out through
Parallel print.
※
If there is an mal-function on Parallel print device,
“PrinT-Er”
will be displayed.
Then, please check the Parallel print device condition.
Function / Clear key Activation display selection
●
0
Activation display not use
F51
1
Activation
display
use
※
Under F51-01 setting, whenever you press “Function” / “Clear” key, “F” or “C” display will be
appear on main display window, and let you know, “Function” or “Clear” key is activated.
Auto Hold Reset selection
●
0
Auto HOLD Reset will not use
F52
1
Auto HOLD Reset use (HOLD Reset at
“
Weight Judge relay output)
※
This function will be applied under F21-02, only.
Counting selection (On Sub Display window)
●
0
PASS Count display
1
Over
Count
display
2
Under Count display
F53
3
N.G Count display (Under + Over)