- 43 -
Weight Judgment Relay Delay time(t3) setting
F22 10
00
∫
99
Delay time period setting, before Weight judgment.
Under F21-01
: Weight Judge after t3 set period, when “Photo Sensor”
input
Under F21-02
: Weight Judge after t3 set period, when “HOLD” input
Under F21-03
: Weight Judge after t3 set period, when weight is
“Steady”.
Under F21-04 : Not applied
※
Under “00” setting : Weight judge will be delayed until weight
is steady.
Weight Judgment Relay “ON” time (t4) setting
F23 10
01
∫
99
After “t3” set period, judge the weight condition and output judgment
relay during the set period.
Under “01” setting : Judgment relay will out during 0.1sec.
Under “20” setting : Judgment relay will out during 2.0sec.
Weight Mode Selection (Absolute Weight / Positive weight mode)
●
0
Absolute Weight mode (Same replay output for
“
-
“
weight)
F25
1
Positive Weight mode (Relay output for only
“
+
”
weight)
※
Under “F25-00” setting, Output relay will be activated both weights, Positive/Negative weight.
※
Under “F25-01” setting, Output relay will be activated only for Positive weight increase/decrease.
N.G Relay “Delay” time (t6) setting
F26 10
01
∫
50
In case of “UNDER”, or “OVER” weight, you can make some delay
time before “N.G” relay output...
Under “01” setting : N.G relay will delay during 0.1sec.
Under “20” setting : N.G relay will delay during 2.0sec.