- 16 -
4-3-3. Load Cell Wire Connection
1). Please connect Indicator’s connector and Load cell cable basis on each color.
2). It is possible to connect Max. 8pcs same capacity load cells with parallel. (350
Ω
)
3). LOAD CELL Connector Standard : N16 - 05
4). The load cell cable color can be different from each manufacturer, please refer following data
sheet.
5). Load Cell Wire Color Chart (Sorted by Manufacturer)
Manufacturers
EXC+
EXC-
SIG+
SIG-
SHIELD
Sewha CNM
Red
White
Green
Blue
Black
Bongshin, CAS ,TMI ,AND
Red
White
Green
Blue Yellow(Shield)
Daesung Red
Black
White
Green
Shield
Power MNC
Red
White
Green
Black
Shield
Disocell Red
Blue
Green
White
Black
Dacell Red
White
Green
Blue
Shield
BLH Green
Black
White
Red
Yellow
INTERFACE Red
Black
Green
White
Shield
KYOWA Red
Black
Green
White
Shield
P.T Red
Black
Green
White
Shield
SHOWA Red
Blue
White
Black
Shield
SHINKOH Red
Black
Green
White
Shield
TML Red
Black
White
Green
Shield
TEAC Red
Blue
White
Black
Yellow
HUNTLEIGH Green
Black
Red
White
Shield
※
Each Wire’s color specification can be changed without prior notice.