- 38 -
◆
Weighing Mode 1. PHOTO SENSOR INPUT MODE
1. Set Value Condition : Over Set value > Under Set value
※
If the setting conditions are not satisfied,
“E”
symbol displayed and you can process the weighing.
2. Weighing Judgment
After Photo Sensor Input, Indicator will delay the judgment during the “t3” set time.
After “t3” set time, indicator will judge the weight and output “Over” / “Under” / “Pass” relay.
During the “Weight Judgment Relay “ON” time, indicator will hold the weight display.
In case of “OVER” or “UNDER”, “Error” relay will be output during the “t5” time period, after “t6”
delay time period
3. External input : please set “F11-00”, only
4. Output Relay
Output
Contents
Output
Contents
Under(1)
Less than “Under” set, “ON”
N.G(4)
Under/Over relay output, “ON”
Over(3)
More than “Over” set, “ON”
Empty(5)
Within the Empty Range “ON”
Pass(2)
Under set
≤
Current Weight
≤
Over set
t5
t5
t6
Weight
Emtpy
Sensor IN
UNDER
OVER
PASS
ERROR
EMPTY
Over Range
Under Range
OVER
UNDER
PASS
t3
t3
t3
t4
t4
t4
Output 1
Output 5
Output 3
Output 2
Output 4
t6