- 71 -
6-4. Analog Output Interface (Option 02 : 0~10V Output)
This Option card converts weight value to Analog Voltage output(0~10V) and transfers to external
devices(Recorder, P.L.C), controlled by voltage output.
6-4-1. Specification
①
. Output Voltage : 0~10V DC output
②
. Accuracy : More than 1/1,000
6-4-2. Circuit
This Voltage output is proportioned on weight calibration and outputs 0~10V.
※
6-4-3. Output Adjustment
①
. This output is adjusted as when the weight is “Zero”, output is 0V and When the weight is
“Full capacity”, output is 10V.
②
. If you need additional adjustment, please adjust with “VR1(Zero)”, “VR2(Span) on the Analog
Output PCB.
Remark
※
This Analog option card converts Displayed weight value(Micro-process data) to analog
value on D/A Converter(Digital to Analog converter)
This D/A Converter has Max. 1/4,000 accuracy, so this output is not suitable for high
accuracy application, like more than 1/3,000.
6-4-4. Connecter (9pin, “D-type” female)
1 : HI(+), 5 : (-)
For 0~5VDC or 1~5VDC analog output, please inform when
※
you inquiry.